Advanced Search
DSpace@MIT

Capillary Break-up Rheometry of Low-Viscosity Elastic Fluids

Research and Teaching Output of the MIT Community

Show simple item record

dc.contributor.author Rodd, Lucy E.
dc.contributor.author Scott, Timothy P.
dc.contributor.author Cooper-White, Justin J.
dc.contributor.author McKinley, Gareth H.
dc.date.accessioned 2005-04-13T13:19:56Z
dc.date.available 2005-04-13T13:19:56Z
dc.date.issued 2004-11-01T13:19:56Z
dc.identifier.uri http://hdl.handle.net/1721.1/16533
dc.description Submitted to Applied Rheology, August 2004 en
dc.description.abstract We investigate the dynamics of the capillary thinning and break-up process for low viscosity elastic fluids such as dilute polymer solutions. Standard measurements of the evolution of the midpoint diameter of the necking fluid filament are augmented by high speed digital video images of the break up dynamics. We show that the successful operation of a capillary thinning device is governed by three important time scales (which characterize the relative importance of inertial, viscous and elastic processes), and also by two important length scales (which specify the initial sample size and the total stretch imposed on the sample). By optimizing the ranges of these geometric parameters, we are able to measure characteristic time scales for tensile stress growth as small as 1 millisecond for a number of model dilute and semi-dilute solutions of polyethylene oxide (PEO) in water and glycerin. If the aspect ratio of the sample is too small, or the total axial stretch is too great, measurements are limited, respectively, by inertial oscillations of the liquid bridge or by the development of the well-known beads-on-a-string morphology which disrupt the formation of a uniform necking filament. By considering the magnitudes of the natural time scales associated with viscous flow, elastic stress growth and inertial oscillations it is possible to construct an “operability diagram” characterizing successful operation of a capillary break-up extensional rheometer. For Newtonian fluids, viscosities greater than approximately 70 mPa.s are required; however for dilute solutions of high molecular weight polymer the minimum viscosity is substantially lower due to the additional elastic stresses arising from molecular extension. For PEO of molecular weight 106 g/mol, it is possible to measure relaxation times of order 1 ms in dilute polymer solutions of viscosity 2 – 10 mPa.s. en
dc.description.sponsorship NSF en
dc.format.extent 1522618 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.relation.ispartofseries 04-P-04;
dc.subject capillary thinning en
dc.subject extensional rheometry en
dc.subject viscoelastic fluid en
dc.title Capillary Break-up Rheometry of Low-Viscosity Elastic Fluids en
dc.type Preprint en


Files in this item

Name Size Format Description
04-P-04.pdf 1.452Mb PDF

This item appears in the following Collection(s)

Show simple item record