Show simple item record

dc.contributor.advisorPeter Hagelstein.en_US
dc.contributor.authorNovosad, Jenniferen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2008-05-19T14:59:24Z
dc.date.available2008-05-19T14:59:24Z
dc.date.copyright2007en_US
dc.date.issued2007en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/41547
dc.descriptionThesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2007.en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.descriptionIncludes bibliographical references (p. 135-139).en_US
dc.description.abstractDue to the finite supply of oil, energy availability and price are issues facing the world. Among the possible approaches to this problem is research of new physical effects which may produce energy in novel ways. The Yang-Koldamasov device was reported to produce excess heat by iESi by pumping oil through a thin nozzle; however, the theoretical mechanism for this effect is at the present unknown. The subject of this thesis is an attempt at independent confirmation of the effect at MIT and FRC. To perform calorimetry on this device, there are several issues involved, such as thermocouple offset errors, RF noise, and erroneous readings due to fluid flow conditions. Methods for handling these issues are discussed in application to two independent measurements of energy gain in the system, differential calorimetry over the cell, and flow calorimetry via a heat exchanger. The differential calorimetry has been improved compared to what was earlier available on Yang-Koldamasov devices, and the flow calorimetry is new to the device. Data was collected on several tests After analysis, the data was found consistent with a null result. However, over the course of the runs the behavior of the device was very different than the behavior at earlier demonstrations where excess heat was observed. For example, earlier demonstrations exhibited electrical arcing perpendicular to the flow of oil, while the current device shows only arcing in the direction of oil flow. Future work is being conducted by FRC to identify the reasons that the current apparatus behaves differently.en_US
dc.description.statementofresponsibilityby Jennifer Novosad.en_US
dc.format.extent139 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleCalorimetric measurements of a Yang-Koldamasov deviceen_US
dc.typeThesisen_US
dc.description.degreeM.Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc220920065en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record