Show simple item record

dc.contributor.advisorJacopo Buongiorno and Lin-Wen Hu.en_US
dc.contributor.authorTruong, Bao H. (Bao Hoai)en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.en_US
dc.date.accessioned2008-05-19T16:08:54Z
dc.date.available2008-05-19T16:08:54Z
dc.date.issued2007en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/41689
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, June 2007.en_US
dc.description"May 2007."en_US
dc.descriptionIncludes bibliographical references (leaves 51-53).en_US
dc.description.abstractNanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed CHF enhancement up to 68% and there seems to be a monotonic relationship between nanoparticle concentration and magnitude of enhancement. Alumina nanofluids had CHF enhancement up to 56% but the peak occurred at the intermediate concentration. The boiling curves in nanofluid were found to shift to the left of that of water and correspond to higher nucleate boiling heat transfer coefficients in the two-phase flow regime. SEM images show a porous coating layer of nanoparticles on wires subjected to nanofluid CHF tests. These coating layers change the morphology of the heater's surface, and are responsible for the CHF enhancement. The thickness of the coating was estimated using SEM and was found ranging from 3.0 to 6.0 micrometers for Alumina, and 3.0 to 15.0 micrometers for Silica. Inductively Coupled Plasma Spectroscopy (ICP-OES) analyses were also attempted to quantify the mass of the particle deposition but the results were inconsistent with the estimates from the SEM measurement.en_US
dc.description.statementofresponsibilityby Bao H. Truong.en_US
dc.format.extent53 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleDetermination of pool boiling Critical Heat Flux enhancement in nanofluidsen_US
dc.title.alternativeDetermination of pool boiling CHF enhancement in nanofluidsen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc221271996en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record