Heat transfer and pressure drop data for high heat flux densities to water at high subcritical pressures
(Cambridge, Mass. : M.I.T. Division of Industrial Cooperation, 1951, 1951)
Local surface ooeffioients of heat t-ansfer, overall pressure drop data and mean friction factor are presented for heat flamms up to 3.52106 BtuAr ft2 for water flowing in a nickel tabe isder the following conditions: mass ...
Burnout in forced convection nucleate boiling of water
(Cambridge, Mass. : M.I.T. Heat Transfer Laboratory, [1957], 1957)
Data are presented for burnout in forced coivection nucleate boiling of water at pressures above 500 psia. A dimensionless correlation is devised for. the M.I.T. data which is found to be valid for certain recent data ...
Void volumes in subcooled boiling systems
(Cambridge, Mass. : M.I.T. Division of Industrial Cooperation, [1958], 1958)
Introduction: Knowledge of the pressure drop in a channel and the resulting flow redistribution is essential in predicting the performance of a nuclear reactor. The pressure drop in a channel which is experiencing boiling ...
Slug flow
(Cambridge, Mass. : Division of Sponsored Research, Massachusetts Institute of Technology, [1959], 1959)
Introduction: When two phases flow concurrently in a pipe, they can distribute themselves in a number of different configurations. The gas could be uniformly dispersed throughout the liquid in the form of small bubbles. ...
Correlation of maximum heat flux data for boiling of saturated liquids
(Cambridge, Mass. : Massachusetts Institute of Technology, Division of Industrial Cooperation, [1955], 1955)
The thermodynamics of bubbles
(Cambridge, Mass. : Massachusetts Institute of Technology, Division of Industrial Cooperation, [1956], 1956)
This paper outlines those concitions annanded by the laws of thermodynamics for equilibriza betwoen the vapor in a bubble and the surrounding liquid and then employs these concepts with a nucleation theory in an atteapt ...
Liquid and gas distributions in a two-phase boiling analogy
(Cambridge, Mass. : Massachusetts Institute of Technology, Division of Industrial Cooperation, [1958], 1958)
This report contains a description of the design and operation of an experimental appats for the analysis of two-phase flows similar to thom occuwring in boiler tubes at low pressures. Velocity and denuity profiles of ...
The correlation of nucleate boiling burn-out data
(Cambridge, Mass. : M.I.T. Division of Industrial Cooperation, [1957], 1957)
A dimensionless correlation is developed for nucleate boiling buzrnout data including the following ranges of variables. Fluids - Water Bensene n - Heptane n - Pentane Ethanol Pressure - 0.0045 to 0.96 of critical pressure ...
Description of boiling project burnout detector
(Cambridge, Mass. : M.I.T. Heat Transfer Laboratory, [1957], 1957)
Introduction: In order to effectively utilize the high heat flux available through the mechanism of nucleate boiling in forced convection heat transfer, it is of primary importance that the maximum flux or "burnout" ...
A method of correlating heat transfer data for surface boiling of liquids
(Cambridge, Mass. : M.I.T. Division of Industrial Cooporation, [1951], 1951)
A method based an a logical uxplanation of the meani of beat transfer associated with the boiling process is presented for correlating heat transfer data for nucleate boiling of liquids for the case of pool boiling. Tbe ...