dc.contributor.author | Kennedy, Brendan F. | |
dc.contributor.author | Curatolo, Andrea | |
dc.contributor.author | Sampson, David D. | |
dc.contributor.author | Hillman, Timothy Robert | |
dc.contributor.author | Saunders, Christobel M. | |
dc.date.accessioned | 2011-09-09T18:58:36Z | |
dc.date.available | 2011-09-09T18:58:36Z | |
dc.date.issued | 2011-02 | |
dc.date.submitted | 2011-01 | |
dc.identifier.issn | 1083-3668 | |
dc.identifier.uri | http://hdl.handle.net/1721.1/65634 | |
dc.description.abstract | We present a technique to reduce speckle in optical coherence tomography images of soft tissues. An average is formed over a set of B-scans that have been decorrelated by viscoelastic creep strain. The necessary correction for the deformation-induced spatial distortions between B-scans is achieved through geometrical co-registration using an affine transformation. Speckle reduction by up to a factor of 1.65 is shown in images of tissue-mimicking soft fibrin phantoms and excised human lymph node tissue with no observable loss of spatial resolution. | en_US |
dc.language.iso | en_US | |
dc.publisher | Society of Photo-optical Instrumentation Engineers | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1117/1.3548239 | en_US |
dc.rights | Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. | en_US |
dc.source | SPIE | en_US |
dc.title | Speckle reduction in optical coherence tomography images using tissue viscoelasticity | en_US |
dc.type | Article | en_US |
dc.identifier.citation | Kennedy, Brendan F. et al. “Speckle reduction in optical coherence tomography images using tissue viscoelasticity.” Journal of Biomedical Optics 16 (2011): 020506. © 2011 Society of Photo-Optical Instrumentation Engineers. | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Spectroscopy Laboratory | en_US |
dc.contributor.approver | Hillman, Timothy Robert | |
dc.contributor.mitauthor | Hillman, Timothy Robert | |
dc.relation.journal | Journal of Biomedical Optics | en_US |
dc.eprint.version | Final published version | en_US |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
dspace.orderedauthors | Kennedy, Brendan F.; Curatolo, Andrea; Hillman, Timothy R.; Saunders, Christobel M.; Sampson, David D. | en |
mit.license | PUBLISHER_POLICY | en_US |
mit.metadata.status | Complete | |