Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. Computer Science and Artificial Intelligence Lab (CSAIL)
  3. Artificial Intelligence Lab Publications
  4. AI Technical Reports (1964 - 2004)
  5. Enhanced Reality Visualization in a Surgical Environment

Enhanced Reality Visualization in a Surgical Environment

Thumbnail Image
Download
Name

AITR-1544.pdf

Size

5.03 MB

Format

Adobe PDF

Checksum (MD5)

4e0a6691377fa039b89264491b84daf6

Thumbnail Image
Download
Name

AITR-1544.ps

Size

18.73 MB

Format

PostScript

Checksum (MD5)

98ebd769b034681249dd1a3238cc4879

Author(s)
Mellor, J.P.
Date Issued
January 1, 1995
Series/Report no.
AITR-1544
Abstract
Enhanced reality visualization is the process of enhancing an image by adding to it information which is not present in the original image. A wide variety of information can be added to an image ranging from hidden lines or surfaces to textual or iconic data about a particular part of the image. Enhanced reality visualization is particularly well suited to neurosurgery. By rendering brain structures which are not visible, at the correct location in an image of a patient's head, the surgeon is essentially provided with X-ray vision. He can visualize the spatial relationship between brain structures before he performs a craniotomy and during the surgery he can see what's under the next layer before he cuts through. Given a video image of the patient and a three dimensional model of the patient's brain the problem enhanced reality visualization faces is to render the model from the correct viewpoint and overlay it on the original image. The relationship between the coordinate frames of the patient, the patient's internal anatomy scans and the image plane of the camera observing the patient must be established. This problem is closely related to the camera calibration problem. This report presents a new approach to finding this relationship and develops a system for performing enhanced reality visualization in a surgical environment. Immediately prior to surgery a few circular fiducials are placed near the surgical site. An initial registration of video and internal data is performed using a laser scanner. Following this, our method is fully automatic, runs in nearly real-time, is accurate to within a pixel, allows both patient and camera motion, automatically corrects for changes to the internal camera parameters (focal length, focus, aperture, etc.) and requires only a single image.
Persistent DSpace Link
http://hdl.handle.net/1721.1/7062
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.