Choriocapillaris and Choroidal Microvasculature Imaging with Ultrahigh Speed OCT Angiography
Name
Choi-2013-Choriocapillaris and.pdf
Size
5.06 MB
Format
Adobe PDF
Checksum (MD5)
f2084e7c23c61f1301b6da2401757cc1
Author(s) • • • • • • • • •
Jayaraman, Vijaysekhar
Cable, Alex E.
Duker, Jay S.
Huber, Robert
Fujimoto, James G.
Choi, Woo Jhon
Mohler, Kathrin Juliane
Potsaid, Benjamin M.
Lu, Chen David
Liu, Jonathan Jaoshin
Date Issued
December 2013
Journal
PLoS ONE
Publisher
Public Library of Science
Citation
Choi, WooJhon, Kathrin J. Mohler, Benjamin Potsaid, Chen D. Lu, Jonathan J. Liu, Vijaysekhar Jayaraman, Alex E. Cable, Jay S. Duker, Robert Huber, and James G. Fujimoto. “Choriocapillaris and Choroidal Microvasculature Imaging with Ultrahigh Speed OCT Angiography.” Edited by Andreas Wedrich. PLoS ONE 8, no. 12 (December 11, 2013): e81499.
Version
Final published version
Abstract
We demonstrate in vivo choriocapillaris and choroidal microvasculature imaging in normal human subjects using optical coherence tomography (OCT). An ultrahigh speed swept source OCT prototype at 1060 nm wavelengths with a 400 kHz A-scan rate is developed for three-dimensional ultrahigh speed imaging of the posterior eye. OCT angiography is used to image three-dimensional vascular structure without the need for exogenous fluorophores by detecting erythrocyte motion contrast between OCT intensity cross-sectional images acquired rapidly and repeatedly from the same location on the retina. En face OCT angiograms of the choriocapillaris and choroidal vasculature are visualized by acquiring cross-sectional OCT angiograms volumetrically via raster scanning and segmenting the three-dimensional angiographic data at multiple depths below the retinal pigment epithelium (RPE). Fine microvasculature of the choriocapillaris, as well as tightly packed networks of feeding arterioles and draining venules, can be visualized at different en face depths. Panoramic ultra-wide field stitched OCT angiograms of the choriocapillaris spanning ~32 mm on the retina show distinct vascular structures at different fundus locations. Isolated smaller fields at the central fovea and ~6 mm nasal to the fovea at the depths of the choriocapillaris and Sattler's layer show vasculature structures consistent with established architectural morphology from histological and electron micrograph corrosion casting studies. Choriocapillaris imaging was performed in eight healthy volunteers with OCT angiograms successfully acquired from all subjects. These results demonstrate the feasibility of ultrahigh speed OCT for in vivo dye-free choriocapillaris and choroidal vasculature imaging, in addition to conventional structural imaging.