Development of Electrospun Polyacrylonitrile Aerosol Filter Media for Respiratory Personal Protective Equipment
Name
em-2024-00083s_ms_clean.pdf
Description
Accepted version
Size
2.9 MB
Format
Adobe PDF
Checksum (MD5)
f11068ef92ab56e21dfc9483bc59cb0b
Author(s) • • •
Ewell, Nathan
Lee, Jeonyoon
Mulherin, Kristen
Rutledge, Gregory C
Date Issued
April 15, 2024
Journal
ACS Applied Engineering Materials
Publisher
American Chemical Society
Citation
Development of Electrospun Polyacrylonitrile Aerosol Filter Media for Respiratory Personal Protective Equipment. Nathan Ewell, Jeonyoon Lee, Kristen Mulherin, and Gregory C. Rutledge. ACS Applied Engineering Materials 2024 2 (4), 1082-1093.
Version
Author's final manuscript
Abstract
The COVID-19 pandemic highlighted the importance of respiratory personal protective equipment (PPE) as a means of reducing the spread of disease via aerosolized droplets. For years, N95-type filtering facepiece respirators based on meltblown polypropylene nonwovens have been the technology of choice for healthcare professionals and personal use. However, their reliance on electrostatic charges to achieve an acceptable trade-off between filtration efficiency and pressure drop has led to concerns about shelf life, reusability, quality control, and versatility of materials. In this study, we show that media in which an electrospun polyacrylonitrile (PAN) nonwoven serves as the active layer, comprising fibers of much smaller diameter than typical meltblown fibers, can achieve high levels of filtration efficiency combined with low pressure drop without the assistance of electrostatic charging. Moreover, the aerosol filtration data is well-described by the slip flow-modified Kuwabara model for pressure drop and a single fiber efficiency model that takes into account particle collection via diffusion, interception, and impaction. These models may be used to guide the further design of nanofiber filters. Combined with a spunbond substrate, the proposed filtration media resolves practical concerns regarding mechanical robustness and residual solvent, and it has been fabricated into filtering facepiece respirators that meet N95 filtration standards when tested by standard methods.
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
10.1021/acsaenm.4c00083