Wake behavior downstream of a transonic compressor rotor
Name
02133215.pdf
Size
1.62 MB
Format
Adobe PDF
Checksum (MD5)
d1dc965d754103683ae836e7d0c75ac6
Author(s)
Stephens, Harry Elias
Date Issued
1974
Publisher
Cambridge, Mass. : Gas Turbine Laboratory, Massachusetts Institute of Technology, 1974
Series/Report no.
GTL report #118
Abstract
Measurements of the static pressure resolved in radial and axial directions downstream of a transonic compressor rotor have been harmonically analyzed. The investigation is part of a program addressing the behavior of disturbances in strongly swirling flows. There is evidence that the wakes are radially outward and carry static pressure disturbances with them. The harmonic analysis of the static pressure measured at the tip radius indicates a shift toward higher frequency of the peak in the power spectrum as the flow proceeds downstream. It is suggested that this increasing frequency associated with the power peak results from the wakes being convected downstream in a fluid which has increasing swirl velocity as it travels away from the rotor.
Description
August 1974
Also issued as: Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 1974
Includes bibliographical references (page 64)