  5. Motion artifact reduction for wearable photoplethysmogram sensors using micro accelerometers and laguerre series adaptive filters

Motion artifact reduction for wearable photoplethysmogram sensors using micro accelerometers and laguerre series adaptive filters

Thumbnail Image
Download
Name

301739805-MIT.pdf

Description
Full printable version
Size

8.04 MB

Format

Adobe PDF

Checksum (MD5)

cc071fb8ffb5a6ad2d6557fc2a51e2fc

Author(s)
Wood, Levi Benjamin
Advisor(s)
H. Harry Asada.
Date Issued
2008
Publisher
Massachusetts Institute of Technology
Abstract
The photoplethysmogram (PPG) is an extremely useful wearable sensing medical diagnostic tool. However, the PPG signal becomes highly corrupted when the wearer is in motion, rendering the measured signal useless. This thesis develops an adaptive motion artifact reduction scheme to recover the underlying physiologic information from the corrupted signal using a collocated accelerometer as a motion reference and adaptively estimating the motion-to-artifact system dynamics. It has previously been shown that this artifact reduction scheme can be utilized, but many tunable parameters were required to model the system dynamics and performance was poor. This work quantifies algorithm performance based on confidence in the estimated system dynamics, which shows low confidence using the previous parameterization when the wearer is jogging. To improve confidence, the form of the system dynamics is established and a Laguerre series is implimented to compactly represent the system dynamics using just a few parameters that can be confidently estimated. Using the new model, heart rate and amplitude can be estimated from typical jogger data with variance similar to separate PPG sensors located on contralateral motionless hands. The standard artifact reduction scheme does not work when the physiologic signal is correlated with wearer motion. Since the signals may become correlated, this work develops a method of recovering the physiological signal even when it is correlated with wearer motion by adapting blind source seperation techniques. However, the success of this new method is limited.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.
Includes bibliographical references (p. 73-74).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/44855
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.