High Resolution Live Cell Raman Imaging Using Subcellular Organelle-Targeting SERS-Sensitive Gold Nanoparticles with Highly Narrow Intra-Nanogap
Name
nihms665622.pdf
Size
1.01 MB
Format
Adobe PDF
Checksum (MD5)
6fe47308dada63c6e222c21c020053e4
Author(s) • • •
Kang, Jeon Woong
So, Peter T. C.
Dasari, Ramachandra Rao
Lim, Dong Kwon
Date Issued
February 2015
Journal
Nano Letters
Publisher
American Chemical Society (ACS)
Citation
Kang, Jeon Woong, Peter T. C. So, Ramachandra R. Dasari, and Dong-Kwon Lim. “High Resolution Live Cell Raman Imaging Using Subcellular Organelle-Targeting SERS-Sensitive Gold Nanoparticles with Highly Narrow Intra-Nanogap.” Nano Letters 15, no. 3 (February 11, 2015): 1766–1772.
Version
Author's final manuscript
Abstract
We report a method to achieve high speed and high resolution live cell Raman images using small spherical gold nanoparticles with highly narrow intra-nanogap structures responding to NIR excitation (785 nm) and high-speed confocal Raman microscopy. The three different Raman-active molecules placed in the narrow intra-nanogap showed a strong and uniform Raman intensity in solution even under transient exposure time (10 ms) and low input power of incident laser (200 μW), which lead to obtain high-resolution single cell image within 30 s without inducing significant cell damage. The high resolution Raman image showed the distributions of gold nanoparticles for their targeted sites such as cytoplasm, mitochondria, or nucleus. The high speed Raman-based live cell imaging allowed us to monitor rapidly changing cell morphologies during cell death induced by the addition of highly toxic KCN solution to cells. These results strongly suggest that the use of SERS-active nanoparticle can greatly improve the current temporal resolution and image quality of Raman-based cell images enough to obtain the detailed cell dynamics and/or the responses of cells to potential drug molecules.
MIT Department
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Chemistry
Massachusetts Institute of Technology. Department of Mechanical Engineering
Massachusetts Institute of Technology. Spectroscopy Laboratory
Koch Institute for Integrative Cancer Research at MIT
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1021/NL504444W