Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Graduate Theses
  5. High Resolution Quantitative Auto-Radiography to determine microscopic distributions of B-10 in neutron capture therapy

High Resolution Quantitative Auto-Radiography to determine microscopic distributions of B-10 in neutron capture therapy

Thumbnail Image
Download
Name

213435393-MIT.pdf

Description
Full printable version
Size

4.82 MB

Format

Adobe PDF

Checksum (MD5)

6837b1a93971eb4c43178c1778204b87

Author(s)
Harris, Thomas C. (Thomas Cameron)
Advisor(s)
Otto K. Harling and Jeffrey A. Coderre.
Alternative Title
HRQAR to determine microscopic distributions of B-10 in neutron capture therapy
Date Issued
2006
Publisher
Massachusetts Institute of Technology
Abstract
The success of Boron Neutron Capture Therapy (BNCT) is heavily dependent on the microscopic distribution of B-10 in tissue. High Resolution Quantitative Auto-Radiography (HRQAR) is a potentially valuable analytical tool due to its ability to simultaneously visualize boron distributions and tissue histology. While powerful, the technique has fallen into disuse, largely due to its complexity. HRQAR was reconstituted, and its accuracy was verified with test samples. Numerous improvements were made to make the process easier and more efficient. Permanent staff members at the Institute were trained in the technique, ensuring the continued vitality of HRQAR. The image acquisition equipment and analysis software were modernized, and made more user-friendly. The microdosimetry analysis software was updated to current versions of programming environments and personal computer operating systems. Verification tests were conducted to ensure the continued accuracy of the underlying algorithms. Several experiments were conducted to demonstrate the applications of HRQAR. One focus of current BNCT research is the development of new boron delivery agents, so a potential new compound was compared with a current-generation boron compound. In order to underscore the broader range of utility of HRQAR, another experiment was conducted using the auto-radiography technique as verification of selective microvasculature irradiation.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2006.
Includes bibliographical references.
Subjects
Nuclear Science and Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/41271
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.