Multidirectional In Vivo Characterization of Skin Using Wiener Nonlinear Stochastic System Identification Techniques
Name
Hunter_Multidirectional in vivo.pdf
Size
2.82 MB
Format
Adobe PDF
Checksum (MD5)
d540246c511bdb68e7e142bb26d53baf
Author(s) • • • • •
Parker, Matthew D.
Taberner, A. J.
Nash, M. P.
Nielsen, P. M. F.
Jones, Lynette A
Hunter, Ian
Date Issued
November 2016
Journal
Journal of Biomechanical Engineering
Publisher
ASME International
Citation
Parker, Matthew D. et al. “Multidirectional In Vivo Characterization of Skin Using Wiener Nonlinear Stochastic System Identification Techniques.” Journal of Biomechanical Engineering 139.1 (2016): 011004. © 2017 ASME
Version
Final published version
Abstract
A triaxial force-sensitive microrobot was developed to dynamically perturb skin in multiple deformation modes, in vivo. Wiener static nonlinear identification was used to extract the linear dynamics and static nonlinearity of the force–displacement behavior of skin. Stochastic input forces were applied to the volar forearm and thenar eminence of the hand, producing probe tip perturbations in indentation and tangential extension. Wiener static nonlinear approaches reproduced the resulting displacements with variances accounted for (VAF) ranging 94–97%, indicating a good fit to the data. These approaches provided VAF improvements of 0.1–3.4% over linear models. Thenar eminence stiffness measures were approximately twice those measured on the forearm. Damping was shown to be significantly higher on the palm, whereas the perturbed mass typically was lower. Coefficients of variation (CVs) for nonlinear parameters were assessed within and across individuals. Individual CVs ranged from 2% to 11% for indentation and from 2% to 19% for extension. Stochastic perturbations with incrementally increasing mean amplitudes were applied to the same test areas. Differences between full-scale and incremental reduced-scale perturbations were investigated. Different incremental preloading schemes were investigated. However, no significant difference in parameters was found between different incremental preloading schemes. Incremental schemes provided depth-dependent estimates of stiffness and damping, ranging from 300 N/m and 2 Ns/m, respectively, at the surface to 5 kN/m and 50 Ns/m at greater depths. The device and techniques used in this research have potential applications in areas, such as evaluating skincare products, assessing skin hydration, or analyzing wound healing.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1115/1.4034993