Assigning Robust Default Values in Building Performance Simulation Software for Improved Decision-Making in the Initial Stages of Building Design

Thumbnail Image
Download
Name

Hiyama_Assigning robust.pdf

Size

1.77 MB

Format

Adobe PDF

Checksum (MD5)

870986edde6d5074639606ec66109549

Author(s)
Hiyama, Kyosuke
Date Issued
2015
Journal
The Scientific World Journal
Publisher
Hindawi (The Scientific World)
Citation
Hiyama, Kyosuke. “Assigning Robust Default Values in Building Performance Simulation Software for Improved Decision-Making in the Initial Stages of Building Design.” The Scientific World Journal 2015 (2015): 1–11.
Version
Final published version
Abstract
Applying data mining techniques on a database of BIM models could provide valuable insights in key design patterns implicitly present in these BIM models. The architectural designer would then be able to use previous data from existing building projects as default values in building performance simulation software for the early phases of building design. The author has proposed the method to minimize the magnitude of the variation in these default values in subsequent design stages. This approach maintains the accuracy of the simulation results in the initial stages of building design. In this study, a more convincing argument is presented to demonstrate the significance of the new method. The variation in the ideal default values for different building design conditions is assessed first. Next, the influence of each condition on these variations is investigated. The space depth is found to have a large impact on the ideal default value of the window to wall ratio. In addition, the presence or absence of lighting control and natural ventilation has a significant influence on the ideal default value. These effects can be used to identify the types of building conditions that should be considered to determine the ideal default values.
MIT Department
Massachusetts Institute of Technology. Department of Architecture
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/98138
DOI of Published Version
https://doi.org/10.1155/2015/246718
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.