Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Retinal nerve fibre layer and visual function loss in glaucoma: the tipping point

Retinal nerve fibre layer and visual function loss in glaucoma: the tipping point

Thumbnail Image
Download
Name

Wollstein-2012-Retinal nerve fibre layer and visual function loss in.pdf

Size

364.41 KB

Format

Adobe PDF

Checksum (MD5)

325b6b8a07b9101b72719307b68fd929

Author(s)
Wollstein, Gadi
•
Kagemann, Larry
•
Bilonick, Richard A.
•
Ishikawa, Hiroshi
•
Folio, Lindsey S.
•
Gabriele, Michelle L.
•
Ungar, Allison K.
•
Duker, Jay S.
•
Fujimoto, James G.
•
Schuman, Joel S.
Date Issued
April 2011
Journal
British Journal of Ophthalmology
Publisher
BMJ Publishing Group
Citation
Wollstein, G. et al. “Retinal Nerve Fibre Layer and Visual Function Loss in Glaucoma: The Tipping Point.” British Journal of Ophthalmology 96.1 (2011): 47–52. Web. © 2011 by the BMJ Publishing Group Ltd.
Version
Final published version
Abstract
Aims To determine the retinal nerve fibre layer (RNFL) thickness at which visual field (VF) damage becomes detectable and associated with structural loss. Methods In a prospective cross-sectional study, 72 healthy and 40 glaucoma subjects (one eye per subject) recruited from an academic institution had VF examinations and spectral domain optical coherence tomography (SD-OCT) optic disc cube scans (Humphrey field analyser and Cirrus HD-OCT, respectively). Comparison of global mean and sectoral RNFL thicknesses with VF threshold values showed a plateau of threshold values at high RNFL thicknesses and a sharp decrease at lower RNFL thicknesses. A ‘broken stick’ statistical model was fitted to global and sectoral data to estimate the RNFL thickness ‘tipping point’ where the VF threshold values become associated with the structural measurements. The slope for the association between structure and function was computed for data above and below the tipping point. Results The mean RNFL thickness threshold for VF loss was 75.3 μm (95% CI: 68.9 to 81.8), reflecting a 17.3% RNFL thickness loss from age-matched normative value. Above the tipping point, the slope for RNFL thickness and threshold value was 0.03 dB/μm (CI: −0.02 to 0.08) and below the tipping point, it was 0.28 dB/μm (CI: 0.18 to 0.38); the difference between the slopes was statistically significant (p<0.001). A similar pattern was observed for quadrant and clock-hour analysis. Conclusions Substantial structural loss (∼17%) appears to be necessary for functional loss to be detectable using the current testing methods
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/70600
DOI of Published Version
https://doi.org/10.1136/bjo.2010.196907
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.