Effect of entropy generation on the performance of humidification-dehumidification desalination cycles
Name
Effect-of-entropy-generation-on-the-performance-of-HDH-cycles.pdf
Size
599.55 KB
Format
Adobe PDF
Checksum (MD5)
0d62bfc767c742e2e513dcdfccf65f9f
Author(s) • •
Zubair, Syed M.
Mistry, Karan Hemant
Lienhard, John H
Date Issued
June 2010
Journal
International Journal of Thermal Sciences
Publisher
Elsevier
Citation
Mistry, Karan H., John H. Lienhard, and Syed M. Zubair. “Effect of Entropy Generation on the Performance of Humidification-Dehumidification Desalination Cycles.” International Journal of Thermal Sciences 49, no. 9 (September 2010): 1837–1847.
Version
Author's final manuscript
Abstract
This paper applies irreversibility analysis to characterize humidification-dehumidification (HD) desalination cycles and to identify how to further improve cycles and components. It is shown that minimizing specific entropy generation of the cycle maximizes the gained output ratio (GOR). It is also shown that each cycle has one limiting component that cannot be substantially improved and a second component that should be the target of efforts to minimize entropy generation. Finally, the failure of exergy analysis to yield conclusive results for on-design HD cycle analysis is discussed briefly.
MIT Department
Massachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Lab
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1016/j.ijthermalsci.2010.05.002