A Comparison of Propofol- and Dexmedetomidine-induced Electroencephalogram Dynamics Using Spectral and Coherence Analysis
Name
Brown_A comparison.pdf
Size
1.71 MB
Format
Adobe PDF
Checksum (MD5)
1ee5ab50957810933c32ad556cc9fb0a
Author(s) • • • • • • • • •
Akeju, Oluwaseun
Pavone, Kara J.
Westover, M. Brandon
Vazquez, Rafael
Prerau, Michael J.
Harrell, Priscilla G.
Hartnack, Katharine E.
Rhee, James
Sampson, Aaron L.
Habeeb, Kathleen
Date Issued
November 2014
Journal
Anesthesiology
Publisher
Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins
Citation
Akeju, Oluwaseun, Kara J. Pavone, M. Brandon Westover, Rafael Vazquez, Michael J. Prerau, Priscilla G. Harrell, Katharine E. Hartnack, et al. “A Comparison of Propofol- and Dexmedetomidine-Induced Electroencephalogram Dynamics Using Spectral and Coherence Analysis.” Anesthesiology 121, no. 5 (November 2014): 978–989.
Version
Author's final manuscript
Abstract
Background:: Electroencephalogram patterns observed during sedation with dexmedetomidine appear similar to those observed during general anesthesia with propofol. This is evident with the occurrence of slow (0.1 to 1 Hz), delta (1 to 4 Hz), propofol-induced alpha (8 to 12 Hz), and dexmedetomidine-induced spindle (12 to 16 Hz) oscillations. However, these drugs have different molecular mechanisms and behavioral properties and are likely accompanied by distinguishing neural circuit dynamics.
Methods:: The authors measured 64-channel electroencephalogram under dexmedetomidine (n = 9) and propofol (n = 8) in healthy volunteers, 18 to 36 yr of age. The authors administered dexmedetomidine with a 1-µg/kg loading bolus over 10 min, followed by a 0.7 µg kg−1 h−1 infusion. For propofol, the authors used a computer-controlled infusion to target the effect-site concentration gradually from 0 to 5 μg/ml. Volunteers listened to auditory stimuli and responded by button press to determine unconsciousness. The authors analyzed the electroencephalogram using multitaper spectral and coherence analysis.
Results:: Dexmedetomidine was characterized by spindles with maximum power and coherence at approximately 13 Hz (mean ± SD; power, −10.8 ± 3.6 dB; coherence, 0.8 ± 0.08), whereas propofol was characterized with frontal alpha oscillations with peak frequency at approximately 11 Hz (power, 1.1 ± 4.5 dB; coherence, 0.9 ± 0.05). Notably, slow oscillation power during a general anesthetic state under propofol (power, 13.2 ± 2.4 dB) was much larger than during sedative states under both propofol (power, −2.5 ± 3.5 dB) and dexmedetomidine (power, −0.4 ± 3.1 dB).
Conclusion:: The results indicate that dexmedetomidine and propofol place patients into different brain states and suggest that propofol enables a deeper state of unconsciousness by inducing large-amplitude slow oscillations that produce prolonged states of neuronal silence.
MIT Department
Institute for Medical Engineering and Science
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Picower Institute for Learning and Memory
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1097/aln.0000000000000419