A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems
Name
A novel point-of-care.pdf
Size
1.1 MB
Format
Adobe PDF
Checksum (MD5)
5a81c23c63cd34471cb9c3234f720b2c
Author(s) • • • • • • • • •
Sohn, Kwanghyun
Merchant, Faisal M.
Sayadi, Omid
Puppala, Dheeraj
Doddamani, Rajiv
Sahani, Ashish
Singh, Jagmeet P.
Heist, E. Kevin
Isselbacher, Eric M.
Armoundas, Antonis
Date Issued
March 2017
Journal
Scientific Reports
Publisher
Nature Publishing Group
Citation
Sohn, Kwanghyun; Merchant, Faisal M.; Sayadi, Omid; Puppala, Dheeraj; Doddamani, Rajiv; Sahani, Ashish; Singh, Jagmeet P.; Heist, E. Kevin; Isselbacher, Eric M. and Armoundas, Antonis A. “A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems.” Scientific Reports 7 (March 2017): 44946 © 2017 The Author(s)
Version
Final published version
Abstract
Cardio-respiratory monitoring is one of the most demanding areas in the rapidly growing, mobile-device, based health care delivery. We developed a 12-lead smartphone-based electrocardiogram (ECG) acquisition and monitoring system (called “cvrPhone”), and an application to assess underlying ischemia, and estimate the respiration rate (RR) and tidal volume (TV) from analysis of electrocardiographic (ECG) signals only. During in-vivo swine studies (n = 6), 12-lead ECG signals were recorded at baseline and following coronary artery occlusion. Ischemic indices calculated from each lead showed statistically significant (p < 0.05) increase within 2 min of occlusion compared to baseline. Following myocardial infarction, spontaneous ventricular tachycardia episodes (n = 3) were preceded by significant (p < 0.05) increase of the ischemic index ~1–4 min prior to the onset of the tachy-arrhythmias. In order to assess the respiratory status during apnea, the mechanical ventilator was paused for up to 2 min during normal breathing. We observed that the RR and TV estimation algorithms detected apnea within 7.9 ± 1.1 sec and 5.5 ± 2.2 sec, respectively, while the estimated RR and TV values were 0 breaths/min and less than 100 ml, respectively. In conclusion, the cvrPhone can be used to detect myocardial ischemia and periods of respiratory apnea using a readily available mobile platform.
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Terms of Use
Creative Commons Attribution 4.0 International License
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1038/srep44946