First results from the MIT optical rapid imaging system (MORIS) on the IRTF: A stellar occultation by Pluto and a transit by exoplanet XO-2b
Name
Elliot_First results.pdf
Size
1.82 MB
Format
Adobe PDF
Checksum (MD5)
a135f96bb9835a435ba1a3bdf75be012
Author(s) • • • • • • • • •
Gulbis, Amanda A. S.
Bus, S. J.
Rayner, J. T.
Stahlberger, W. E.
Rojas, Folkers E.
Adams, Elisabeth Rose
Person, Michael J.
Chung, R.
Tokunaga, A. T.
Zuluaga, Carlos Andres
Date Issued
April 2011
Journal
Publications of the Astronomical Society of the Pacific
Publisher
University of Chicago Press, The
Citation
Gulbis, A. A. S. et al. “First Results from the MIT Optical Rapid Imaging System (MORIS) on the IRTF: A Stellar Occultation by Pluto and a Transit by Exoplanet XO-2b.” Publications of the Astronomical Society of the Pacific 123.902 (2011): 461–469.
Version
Author's final manuscript
Abstract
We present a high-speed, visible-wavelength imaging instrument: MORIS (the MIT Optical Rapid Imaging System). MORIS is mounted on the 3 m Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii. Its primary component is an Andor iXon camera, a nearly 60" square field of view with high quantum efficiency, low read noise, low dark current, and full-frame readout rates ranging from as slow as desired to a maximum of between 3.5 Hz and 35 Hz (depending on the mode; read noise of 6 pixel and 49 pixel with electron-multiplying gain = 1 , respectively). User-selectable binning and subframing can increase the cadence to a few hundred hertz. An electron-multiplying mode can be employed for photon counting, effectively reducing the read noise to subelectron levels at the expense of dynamic range. Data cubes, or individual frames, can be triggered to several-nanosecond accuracy using the Global Positioning System. MORIS is mounted on the side-facing exit window of SpeX, allowing simultaneous near-infrared and visible observations. Here, we describe the components, setup, and measured characteristics of MORIS. We also report results from the first science observations: the 2008 June 24 stellar occultation by Pluto and an extrasolar planetary transit by XO-2b. The Pluto occultation of a 15.8 magnitude star has a signal-to-noise ratio of 35 per atmospheric scale height and a midtime error of 0.32 s. The XO-2b transit reaches photometric precision of 0.5 mmag in 2 minutes and has a midtime timing precision of 23 s.
MIT Department
Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike 3.0
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1086/659636