Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Assessment of Autonomic Control and Respiratory Sinus Arrhythmia Using Point Process Models of Human Heart Beat Dynamics

Assessment of Autonomic Control and Respiratory Sinus Arrhythmia Using Point Process Models of Human Heart Beat Dynamics

Thumbnail Image
Download
Name

Chen_Assessment-of-Automatic.pdf

Size

627.87 KB

Format

Adobe PDF

Checksum (MD5)

685812397995880e67008be31485c13b

Author(s)
Chen, Zhe
•
Brown, Emery N.
•
Barbieri, Riccardo
Date Issued
June 2009
Journal
IEEE Transactions on Biomedical Engineering
Publisher
Institute of Electrical and Electronics Engineers
Citation
Zhe Chen, E.N. Brown, and R. Barbieri. “Assessment of Autonomic Control and Respiratory Sinus Arrhythmia Using Point Process Models of Human Heart Beat Dynamics.” Biomedical Engineering, IEEE Transactions on 56.7 (2009): 1791-1802. Print. © 2009 Institute of Electrical and Electronics Engineers
Version
Final published version
Abstract
Tracking the autonomic control and respiratory sinus arrhythmia (RSA) from electrocardiogram and respiratory measurements is an important problem in cardiovascular control. We propose a point process adaptive filter algorithm based on an inverse Gaussian model to track heart beat intervals that incorporates respiratory measurements as a covariate and provides an analytic form for computing a dynamic estimate of RSA gain. We use Kolmogorov-Smirnov tests and autocorrelation function analyses to assess model goodness-of-fit. We illustrate the properties of the new dynamic estimate of RSA in the analysis of simulated heart beat data and actual heart beat data recorded from subjects in a four-state postural study of heart beat dynamics: control, sympathetic blockade, parasympathetic blockade, and combined sympathetic and parasympathetic blockade. In addition to giving an accurate description of the heart beat data, our adaptive filter algorithm confirms established findings pointing at a vagally mediated RSA and provides a new dynamic RSA estimate that can be used to track cardiovascular control between and within a broad range of postural, pharmacological, and age conditions. Our paradigm suggests a possible framework for designing a device for ambulatory monitoring and assessment of autonomic control in both laboratory research and clinical practice.
MIT Department
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Massachusetts Institute of Technology. Neuroscience Statistics Research Laboratory
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/51871
DOI of Published Version
http://dx.doi.org/10.1109/tbme.2009.2016349