Photoplethysmography for non-invasive measurement of bone hemodynamic responses to changes in external pressure
Name
758485297-MIT.pdf
Description
Full printable version
Size
14.72 MB
Format
Adobe PDF
Checksum (MD5)
a1f1bc19f5cb2e96702ebe4fc9135755
Author(s)
Mateus, Jaime (Pereira de Mateus Silva)
Advisor(s)
Alan R. Hargens and Dava J. Newman.
Date Issued
2011
Publisher
Massachusetts Institute of Technology
Abstract
Adequate blood supply and circulation in bones is required to maintain a healthy skeleton, and inadequate blood perfusion is associated with numerous bone pathologies and a decrease in bone mineral density (BMD). Bone hemodynamics remains poorly understood and loss of BMD is still one of the limiting factors to long duration human spaceflight. Developments in photoplethysmography (PPG) hardware have made it a promising tool for non-invasive bone hemodynamic measurements. The aims of this thesis are to: 1) validate the use of PPG as a tool for non-invasive bone hemodynamic measurements, 2) characterize bone hemodynamic responses to changes in external pressure, and 3) identify the predominant mechanisms regulating bone hemodynamic responses to pressure changes. A new PPG device capable of measuring bone hemodynamic responses was designed and tested. It represents the state-of-the-art in deep-tissue PPG instrumentation. Validation experiments including arterial occlusion, cold exposure, skin occlusion and nitroglycerin exposure were performed. Single-limb pressure chamber experiments were performed over a range of pressures from -50 to +50 mmHg to characterize the responses to changes in external pressure and to identify the predominant control mechanisms. Our results support the use of PPG as a valid tool for measuring bone hemodynamic responses. Bone hemodynamic responses to changes in external pressure have been characterized for the first time. We also present the first report of a myogenic response in bone and show that the myogenic effect is the predominant control mechanism in bone over a wide range of pressure levels. Myogenic-induced vasoconstriction is observed at all negative pressure levels, with increasing vasoconstriction at the more extreme pressure differences. At positive pressures we observed an initial myogenic-induced vasodilation followed by activation of the intramuscular pressure receptors at +30 mmHg which overrides the initial response and causes vasoconstriction at the highest positive pressure. The availability of a new tool for non-invasive bone hemodynamic measurements opens the door to several new research opportunities with clinical, Earth-based as well as human spaceflight applications.
Description
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2011.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 123-135).
Subjects
Aeronautics and Astronautics.
MIT Department
Massachusetts Institute of Technology. Department of Aeronautics and Astronautics
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
Persistent DSpace Link