Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Doctoral Theses
  5. Simplified methodology for indoor environment designs

Simplified methodology for indoor environment designs

Thumbnail Image
Download
Name

48412858-MIT.pdf

Description
Full printable version
Size

29.48 MB

Format

Adobe PDF

Checksum (MD5)

0da0562689771e1fcbbf7735b27c184d

Author(s)
Srebric, Jelena, 1970-
Advisor(s)
Qingyan Chen.
Date Issued
2000
Publisher
Massachusetts Institute of Technology
Abstract
Current design of the building indoor environment uses averaged single parameters such as air velocity, air temperature or contaminant concentration. This approach gives only general information about thermal comfort and indoor air quality, which is limiting for the design of energy efficient and healthy buildings. The design of these buildings requires sophisticated but practical tools that are not currently available, and the objective of this thesis is to develop such a tool. The development of the simple design tool had several phases. Each phase employed simplified models validated with measured data in order to assess model accuracy and reliability. The validation data was obtained from a state-of-the-art experimental facility at MIT. Based on the collected data, we first developed simplified boundary conditions for the diffuser jet flow, which is the key flow element in mechanically ventilated spaces. The boundary conditions employ resultant momentum from the supply diffusers without modeling the detailed diffuser geometry. Although simple, the models can simulate airflow from complex diffusers commonly used for air-conditioning with reasonable accuracy. Another simplification is the use of a zero-equation turbulence model to calculate indoor air distribution. The model uses the concept of eddy-viscosity and approximate turbulent viscosity with an algebraic equation. To test the turbulence model, an airflow program was developed. The program can simulate indoor airflow on a PC within several minutes, which is five to ten times faster than with the similar programs with a "standard" k-£ model. Finally, the airflow program was coupled with an energy analysis program. The combined program simultaneously analyzes internal heat transfer and air movement as well as the heat transfer through the building envelope. The impacts on the thermal comfort in the occupied zone are quantified, and we found that the thermal comfort in most cases is not
Description
Thesis (Ph.D.)--Massachusetts Institute of Technology, Dept. of Architecture, 2000.
Includes bibliographical references (p. 231-237).
Subjects
Architecture.
MIT Department
Massachusetts Institute of Technology. Department of Architecture
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/8831
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.