Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Echo-Time and Field Strength Dependence of BOLD Reactivity in Veins and Parenchyma Using Flow-Normalized Hypercapnic Manipulation

Echo-Time and Field Strength Dependence of BOLD Reactivity in Veins and Parenchyma Using Flow-Normalized Hypercapnic Manipulation

Thumbnail Image
Download
Name

Triantafyllou-2011-Echo-Time and Field.pdf

Size

700.7 KB

Format

Adobe PDF

Checksum (MD5)

9150dee5b278d3acceb677b4e62a8fa7

Author(s)
Hoge, Richard D.
•
Triantafyllou, Christina
•
Wald, Lawrence
Date Issued
September 2011
Journal
PLoS ONE
Publisher
Public Library of Science
Citation
Triantafyllou, Christina, Lawrence L. Wald, and Richard D. Hoge. “Echo-Time and Field Strength Dependence of BOLD Reactivity in Veins and Parenchyma Using Flow-Normalized Hypercapnic Manipulation.” Ed. Chris I. Baker. PLoS ONE 6.9 (2011): e24519. Web. 15 Feb. 2012.
Version
Final published version
Abstract
While the BOLD (Blood Oxygenation Level Dependent) contrast mechanism has demonstrated excellent sensitivity to neuronal activation, its specificity with regards to differentiating vascular and parenchymal responses has been an area of ongoing concern. By inducing a global increase in Cerebral Blood Flow (CBF), we examined the effect of magnetic field strength and echo-time (TE) on the gradient-echo BOLD response in areas of cortical gray matter and in resolvable veins. In order to define a quantitative index of BOLD reactivity, we measured the percent BOLD response per unit fractional change in global gray matter CBF induced by inhaling carbon dioxide (CO[scubript 2]). By normalizing the BOLD response to the underlying CBF change and determining the BOLD response as a function of TE, we calculated the change in R[scubript 2]* (ΔR[scubript 2]*) per unit fractional flow change; the Flow Relaxation Coefficient, (FRC) for 3T and 1.5T in parenchymal and large vein compartments. The FRC in parenchymal voxels was 1.76±0.54 fold higher at 3T than at 1.5T and was 2.96±0.66 and 3.12±0.76 fold higher for veins than parenchyma at 1.5T and 3T respectively, showing a quantitative measure of the increase in specificity to parenchymal sources at 3T compared to 1.5T. Additionally, the results allow optimization of the TE to prioritize either maximum parenchymal BOLD response or maximum parenchymal specificity. Parenchymal signals peaked at TE values of 62.0±11.5 ms and 41.5±7.5 ms for 1.5T and 3T, respectively, while the response in the major veins peaked at shorter TE values; 41.0±6.9 ms and 21.5±1.0 ms for 1.5T and 3T. These experiments showed that at 3T, the BOLD CNR in parenchymal voxels exceeded that of 1.5T by a factor of 1.9±0.4 at the optimal TE for each field.
MIT Department
Martinos Imaging Center (McGovern Institute for Brain Research at MIT)
Harvard University--MIT Division of Health Sciences and Technology
McGovern Institute for Brain Research at MIT
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by/2.5/
Persistent DSpace Link
http://hdl.handle.net/1721.1/69111
DOI of Published Version
https://doi.org/10.1371/journal.pone.0024519
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.