  4. Reduced damage in electron microscopy by using interaction-free measurement and conditional reillumination

Reduced damage in electron microscopy by using interaction-free measurement and conditional reillumination

Thumbnail Image
Download
Name

PhysRevA.99.063809.pdf

Description
Published version
Size

1.91 MB

Format

Adobe PDF

Checksum (MD5)

503187a6be3c2101a686adcd351c254b

sword-2020-12-02T15:00:32.original.xml (130 B)
Original SWORD entry document
Author(s)
Agarwal, Akshay
•
Berggren, Karl K
•
van Staaden, Yuri J.
•
Goyal, Vivek K.
Date Issued
June 2019
Journal
Physical Review A
Publisher
American Physical Society (APS)
Citation
Agarwal, Akshay et al. "Reduced damage in electron microscopy by using interaction-free measurement and conditional reillumination." Physical Review A 99, 6 (June 2019): 063809 © 2019 American Physical Society
Version
Final published version
Abstract
Interaction-free measurement (IFM) has been proposed as a means of high-resolution, low-damage imaging of radiation-sensitive samples, such as biomolecules and proteins. The basic setup for IFM is a Mach-Zehnder interferometer, and recent progress in nanofabricated electron-diffraction gratings has made it possible to incorporate a Mach-Zehnder interferometer in a transmission electron microscope (TEM). Therefore, the limits of performance of IFM with such an interferometer and a shot-noise limited electron source (such as that in a TEM) are of interest. In this paper, we compare the error probability and sample damage for ideal IFM and classical imaging schemes, through theoretical analysis and numerical simulation. We consider a sample that is either completely transparent or completely opaque at each pixel. In our analysis, we also evaluate the impact of an additional detector for scattered electrons. Inclusion of the scattering detector results in reduction of error by up to an order of magnitude, for both IFM and classical schemes. We also investigate a sample reillumination scheme based on updating priors after each round of illumination and find that this scheme further reduces error. Implementation of these methods is likely achievable with existing instrumentation and would result in improved resolution in low-dose electron microscopy.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/128716
DOI of Published Version
https://doi.org/10.1103/physreva.99.063809
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.