Detection of improvised explosive devices at long-range using coded aperture imaging of backscattered X-rays with dynamic reconstruction
Name
547364486-MIT.pdf
Description
Full printable version
Size
34.45 MB
Format
Adobe PDF
Checksum (MD5)
a8c9a9eba366dca6b23450ed902514a3
Author(s)
Bell, Jayna T. (Jayna Teresa)
Advisor(s)
Richard C. Lanza and Jacquelyn C. Yanch.
Alternative Title
Detection of IEDs at long-range using CAI of backscattered X-rays with DR
Date Issued
2009
Publisher
Massachusetts Institute of Technology
Abstract
Standoff detection of improvised explosive devices (IEDs) is a continuing problem for the U.S. military. Current X-ray detection systems cannot detect explosives at distances above a few meters and with a source-detector system moving in relation to the target. The aim of this study is to determine the feasibility of a large-area, Coded-Aperture Imaging (CAI) system using X-Ray backscatter as the source of radiation. A moving source-detector system required development of a new reconstruction technique, dynamic reconstruction (DR), which continually back-projects detected events on an event-by-event basis. This research imaged multiple low-Z (polyethylene and water-filled), area targets with backscattered X-rays using standard medical imaging equipment, coded aperture masks with ideal bi-level autocorrelation properties, and dynamic reconstruction (DR). Lower fill factor apertures were the primary metric investigated because contrast was shown to be inversely related to the mask's percentage of open area. This study experimentally determined the optimal mask fill factor, gamma camera imaging protocols, and experimental geometry by examining the resulting effects on image quality. Reconstructed images were analyzed for Contrast-to-noise ratio (CNR), Signal-to-noise Ratio (SNR), resolution, sharpness, the uniformity of the background (artifacts). In addition to changing the fill factor, additional methods of improving the contrast included changing the experimental geometry, reducing the X-ray tube filtration, and widening the X-ray source's cone beam (FOV).
(cont.) 14 studies were performed that found 25% fill factor mask reconstructions had the highest average CNR (14.7), compared to 50% and 12.5% fill factor (CNRs 8.50 and 6.9, respectively) with a system resolution of 25 mm at the target. Thus, this study's techniques confirmed that large-area, low fill factor coded apertures could successfully be used, in conjunction with dynamic reconstruction, to image complex, extended scenes at 5 meters with capabilities of up to 50 meters or more.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2009.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 117-118).
Subjects
Nuclear Science and Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
Persistent DSpace Link