Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array
Name
092104_1_5.0160893.pdf
Description
Published version
Size
4.76 MB
Format
Adobe PDF
Checksum (MD5)
4583aef3a0c9993d896ebf40a9f4feeb
Author(s) • • • • • • • • •
Datta, R
Angel, J
Greenly, JB
Bland, SN
Chittenden, JP
Lavine, ES
Potter, WM
Robinson, D
Varnish, TWO
Wong, E
Date Issued
September 1, 2023
Journal
Physics of Plasmas
Publisher
AIP Publishing
Citation
R. Datta, J. Angel, J. B. Greenly, S. N. Bland, J. P. Chittenden, E. S. Lavine, W. M. Potter, D. Robinson, T. W. O. Varnish, E. Wong, D. A. Hammer, B. R. Kusse, J. D. Hare; Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array. Phys. Plasmas 1 September 2023; 30 (9): 092104.
Version
Final published version
Abstract
We characterize the plasma flows generated during the ablation stage of an over-massed exploding planar wire array, fielded on the COBRA pulsed-power facility (1 MA peak current, 250 ns rise time). The planar wire array is designed to provide a driving magnetic field (80–100 T) and current per wire distribution (about 60 kA), similar to that in a 10 MA cylindrical exploding wire array fielded on the Z machine. Over-massing the arrays enables continuous plasma ablation over the duration of the experiment without implosion. The requirement to over-mass on the Z machine necessitates wires with diameters of 75–100μm, which are thicker than wires usually fielded on wire array experiments. To test ablation with thicker wires, we perform a parametric study by varying the initial wire diameter between 33 and 100 μm. The largest wire diameter (100 μm) array exhibits early closure of the cathode-wire gap, while the gap remains open over the duration of the experiment for wire diameters between 33 and 75 μm. Laser plasma interferometry and time-gated extreme-ultraviolet (XUV) imaging are used to probe the plasma flows ablating from the wires. The plasma flows from the wires converge to generate a pinch, which appears as a fast-moving (V≈100kms−1) column of increased plasma density (n¯e≈2×1018cm−3) and strong XUV emission. Finally, we compare the results with three-dimensional resistive-magnetohydrodynamic (MHD) simulations performed using the code GORGON, the results of which reproduce the dynamics of the experiment reasonably well.
MIT Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Terms of Use
Creative Commons Attribution
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1063/5.0160893