On the Electrostatics of Pneumatic Conveying of Granular Materials
Name
MEBCS016.pdf
Size
290.17 KB
Format
Adobe PDF
Checksum (MD5)
4d1a750e9353569afbffa41f3b31a687
Author(s) • •
Zhu, Kewu
Yao, Jun
Wang, Chi-Hwa
Date Issued
January 2004
Series/Report no.
Molecular Engineering of Biological and Chemical Systems (MEBCS);
Abstract
In this work the electrostatics of the pneumatic conveying of granular materials in a non-conducting (PVC) vertical pipe is studied using Electrical Capacitance Tomography (ECT) system. The non-conducting wall in general attains static charges arising from particle-wall collisions in the initial periods of conveying process and then reaches equilibrium with the surroundings. The polarity of particles and conveying pipe inner wall agrees reasonably well with the contact potential difference measurements. The perturbations in the capacitance signal due to charge accumulation are larger with smaller air superficial velocity. The denser flow regimes give larger wall residual charge. Wall charging process shows similar trend by surface potential and ECT measurements. The addition of small amount (0.5% by weight) of anti-static agent (Larostat-519) in the powder form decreases the electrostatic charge generation by altering the patterns for particle-particle and particle-wall collisions.
Subjects
pneumatic conveying
granular materials
electrical capacitance tomography
electrostatics
Persistent DSpace Link