New methods for measuring spectral bi-directional transmission and reflection using digital cameras
Name
173260125-MIT.pdf
Description
Full printable version
Size
4.63 MB
Format
Adobe PDF
Checksum (MD5)
35386592ae1588bfce17cc3bc664fe77
Author(s)
Gayeski, Nicholas (Nicholas Thomas)
Advisor(s)
Marilyne Anderson.
Date Issued
2007
Publisher
Massachusetts Institute of Technology
Abstract
Advanced fenestration systems are increasingly being used to distribute solar radiation purposefully in buildings. Distribution of visible light and near infrared radiation can be optimized to enhance daylighting and reduce thermal loads. Light redirecting window systems are one of many innovative fenestration systems available for improving the daylighting and thermal performance of buildings. Many emerging and existing light redirecting systems have both spectrally and angularly selective optical properties. To study these properties, a device that measures the spectral, bi-directional transmission and reflection distribution functions of complex fenestration systems is being developed at the Massachusetts Institute of Technology. This device, a goniophotometer, will measure photometric and radiometric BT(R)DFs for radiation of 380 to 1700 nanometer wavelengths, encompassing much of the solar spectrum. The device incorporates spectroradiometrically calibrated digital cameras and absorption filters to gather quasi-spectral information about reflection and transmission by complex fenestration systems. It relies on a half-mirrored, aluminum coated acrylic hemi-ellipsoid to project reflected or transmitted light towards a digital camera.
(cont.) The device will be able to characterize BT(R)DFs for a variety of fenestration system materials, assemblies, and building materials. The goal of this research is to support the development of innovative, spectrally and angularly selective window systems that can improve daylighting and comfort and/or reduce cooling and heating loads in buildings. This thesis focuses on calibrating digital cameras to measure radiances with unknown spectra, developing the hemi-ellipsoid for the new goniophotometer, and developing methods for constructing quasi-spectral BT(R)DFs using this new device. The calibrated cameras also have potential for use in other applications, for example, as radiometers and photometers in rooms with light of known spectra.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 2007.
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Includes bibliographical references (p. 194-201).
Subjects
Architecture.
MIT Department
Massachusetts Institute of Technology. Department of Architecture
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Persistent DSpace Link