Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Charge shielding effects of PEG bound to NH2-terminated PAMAM dendrimers – an experimental approach

Charge shielding effects of PEG bound to NH2-terminated PAMAM dendrimers – an experimental approach

Thumbnail Image
Download
Name

d2sm01698b.pdf

Description
Published version
Size

2.32 MB

Format

Adobe PDF

Checksum (MD5)

b81459932eaa2aeb5b00509785b6b5e3

sword-2024-09-20T16:13:59.original.xml (130 B)
Original SWORD entry document
Author(s)
Johnston, Brandon M
•
Grodzinsky, Alan J
•
Hammond, Paula T
Date Issued
2023
Journal
Soft Matter
Publisher
Royal Society of Chemistry
Citation
Soft Matter, 2023,19, 3033-3046
Version
Final published version
Abstract
Cationic poly(amido amine) (PAMAM) dendrimers exhibit great potential for use in drug delivery, but their high charge density leads to an inherent cytotoxicity. To increase biocompatibility, many studies have attached poly(ethylene glycol) (PEG) chains to the dendrimer surface. It is unclear how these tethered PEG chains influence the physicochemical properties of the dendrimer. Here, we develop a fluorescence-based assay utilizing anionic biological tissue to quantify the electrostatic binding affinity of a library of PEG–PAMAM conjugates with various PEG chain lengths and grafting densities. We find that covalently bound PEG chains reduce the electrostatic binding affinity more significantly than what can be achieved through covalent bonds only. Contrary to previous thought, this reduction is not explained by the steric hindrance effects of PEG chains, suggesting that other, non-covalent interactions between PEG and PAMAM are present. Using acetylated PAMAM conjugates, we convert electrostatic binding affinity to the number of charged amines accessible to the physiological environment. These data, coupled with 1H-NMR, allows us to study more closely the non-covalent interactions between PEG and PAMAM. We find that increasing PEG chain length increases the number of non-covalent interactions. Additionally, at low grafting densities, increasing the number of PEG chains on the PAMAM surface also increases the non-covalent interactions. At higher grafting densities, however, PEG chains sterically repel one another, forcing chains to elongate away from the surface and reducing the number of interactions between PAMAM and individual PEG chains. The data presented here provides a framework for a more precise mechanistic understanding of how the length and density of tethered PEG chains on PAMAM dendrimers influence drug delivery properties.
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Koch Institute for Integrative Cancer Research at MIT
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/3.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/156916
DOI of Published Version
https://doi.org/10.1039/d2sm01698b
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.