Gas–Liquid Flow and Mass Transfer in an Advanced-Flow Reactor
Name
Jensen_Gas-liquid flow with SI.pdf
Size
3.31 MB
Format
Adobe PDF
Checksum (MD5)
6a5e99d368f5fcc699ab8b8901d88387
Author(s) • •
Nieves-Remacha, Maria Jose
Kulkarni, Amol A.
Jensen, Klavs F.
Date Issued
May 2013
Journal
Industrial & Engineering Chemistry Research
Publisher
American Chemical Society (ACS)
Citation
Nieves-Remacha, Maria Jose, Amol A. Kulkarni, and Klavs F. Jensen. “Gas–Liquid Flow and Mass Transfer in an Advanced-Flow Reactor.” Ind. Eng. Chem. Res. 52, no. 26 (July 3, 2013): 8996–9010.
Version
Author's final manuscript
Abstract
Hydrodynamics and mass transfer of gas–liquid flow are explored under ambient conditions in an Advanced-Flow Reactor (AFR), an emerging commercial system designed for continuous manufacture. Carbon dioxide/water is the model system used in this study for a range of flow rates for gas and liquid of 5.6–103 mL/min and 10–80 mL/min, respectively. Bubble size distribution, gas holdup, specific interfacial area, pressure drop, and mass transfer coefficients are determined from flow visualization experiments and compared with conventional gas–liquid contactors. These variables are mainly influenced by the inlet flow rates and inlet composition. Average bubble sizes ([bar over d][subscript s]) of 0.9–3.8 mm, gas holdup (ε[subscript G]) of 0.04–0.68, specific interfacial areas (a) of 160–1300 m[superscript 2]/m[superscript 3], and overall mass transfer coefficients (k[subscript L]a) of 0.2–3 s[superscript –1] were obtained for the vertical orientation of the AFR. Although effect of gravity is present for this system, no significant effect on the hydrodynamic properties was observed. The measured pressure drop for vertical orientation (3.6–53.4 kPa) was used to estimate power consumption, which is used as a metric to compare mass transfer efficiency among different gas–liquid contactors. A power law relationship was obtained for the overall mass transfer coefficients in terms of power input and gas holdup, given by k[subscript L]a = 0.101P[0.443 over w]ε[0.459 over G]. The design of the AFR with a series of heart-shaped confined sections with obstacles enhances continuous breakup and coalescence of bubbles providing interfacial areas and mass transfer coefficients 1 order of magnitude larger than other gas–liquid contactors, such as bubble columns (50–600 m[superscript 2]/m[superscript 3]; 0.005–0.24 s[superscript –1]) and spray columns (75–170 m[superscript 2]/m[superscript 3]; 0.015–0.022 s[superscript –1]), and 1 order of magnitude smaller than gas–liquid microchannels (3400–9000 m[superscript 2]/m[superscript 3]; 0.3–21 s[superscript –1]) or falling film reactors (20,000 m[superscript 2]/m[superscript 3]).
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1021/ie4011707