Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Graduate Theses
  5. Retrofitting unreinforced concrete masonry to resist tornado loading

Retrofitting unreinforced concrete masonry to resist tornado loading

Thumbnail Image
Download
Name

862810173-MIT.pdf

Description
Full printable version
Size

17.06 MB

Format

Adobe PDF

Checksum (MD5)

d264a05a0f8b4298d27e0c029a2e2c15

Author(s)
Dorshorst, Evan G. (Evan Gregory)
Advisor(s)
Jerome J. Connor.
Date Issued
2013
Publisher
Massachusetts Institute of Technology
Abstract
Advances in structural design and building materials have significantly increased the performance of many structures under the extreme loading conditions associated with natural disasters such as earthquakes. However, catastrophic structural failure after extreme wind events and tornadoes remains a problem which costs the insurance industry billions of dollars and results in an average loss of 200 lives per year in the United States. Accountable for many of these structural failures, buildings with walls of Unreinforced Masonry (URM) are incapable of withstanding the magnitude of forces brought on by a tornado, and the cracking or failure of just one wall can lead to the progressive collapse of the entire structure. The need to reinforce these systems is large, but retrofitting with conventional steel reinforcement is time consuming and costly; however, externally bonded Fiber Reinforced Polymer (FRP) composites represent a high strength, low cost alternative which and can be installed in a fraction of the time. This thesis investigates the use of FRPs to strengthen URM walls against both out-of-plane flexural loads and debris impact, and attempts to determine if enough strength can be added for such wall assemblies to meet the requirements of a Tornado Safe Room as dictated by FEMA. By adapting current design guidelines and extrapolating evidence on the performance of URM walls strengthened with FRP, a design guide is created which provides the tool necessary to use this innovative retrofitting technique to strengthen URM walls to satisfy both the flexural and impact resistance strength requirements for FEMA Tornado Safe Rooms.
Description
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2013.
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Cataloged from student-submitted PDF version of thesis.
Includes bibliographical references (p. 99-101).
Subjects
Civil and Environmental Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/82710
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.