Transcranial LED therapy for cognitive dysfunction in chronic, mild traumatic brain injury: Two case reports
Name
Naeser-2010-Transcranial LED.pdf
Size
222.57 KB
Format
Adobe PDF
Checksum (MD5)
5484e745a4e996d72454760e535a4dc8
Author(s) • • • •
Naeser, Margaret A.
Saltmarche, Anita
Krengel, Maxine H.
Hamblin, Michael R.
Knight, Jeffrey A.
Date Issued
February 2010
Journal
Proceedings of the Society of Photo-optical Instrumentation Engineers
Publisher
Society of Photo-optical Instrumentation Engineers
Citation
Naeser, Margaret A. et al. “Transcranial LED therapy for cognitive dysfunction in chronic, mild traumatic brain injury: two case reports.” Mechanisms for Low-Light Therapy V. Ed. Michael R. Hamblin, Ronald W. Waynant, & Juanita Anders. San Francisco, California, USA: SPIE, 2010. 75520L-12. ©2010 SPIE--The International Society for Optical Engineering.
Version
Final published version
Abstract
Two chronic, traumatic brain injury (TBI) cases are presented, where cognitive function improved following treatment with transcranial light emitting diodes (LEDs). At age 59, P1 had closed-head injury from a motor vehicle accident (MVA) without loss of consciousness and normal MRI, but unable to return to work as development specialist in internet marketing, due to cognitive dysfunction. At 7 years post-MVA, she began transcranial LED treatments with cluster heads (2.1" diameter with 61 diodes each - 9x633nm, 52x870nm; 12-15mW per diode; total power, 500mW; 22.2 mW/cm2) on bilateral frontal, temporal, parietal, occipital and midline sagittal areas (13.3 J/cm2 at scalp, estimated 0.4 J/cm2 to brain cortex per area). Prior to transcranial LED, focused time on computer was 20 minutes. After 2 months of weekly, transcranial LED treatments, increased to 3 hours on computer. Performs nightly home treatments (now, 5 years, age 72); if stops treating >2 weeks, regresses. P2 (age 52F) had history of closed-head injuries related to sports/military training and recent fall. MRI shows fronto-parietal cortical atrophy. Pre-LED, was not able to work for 6 months and scored below average on attention, memory and executive function. Performed nightly transcranial LED treatments at home (9 months) with similar LED device, on frontal and parietal areas. After 4 months of LED treatments, returned to work as executive consultant, international technology consulting firm. Neuropsychological testing (post- 9 months of transcranial LED) showed significant improvement in memory and executive functioning (range, +1 to +2 SD improvement). Case 2 reported reduction in PTSD symptoms.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1117/12.842510