Impact of salt retention on true batch reverse osmosis energy consumption: experiments and model validation
Name
Wei et al - batchRoSaltRetention - Desalination - preprint.pdf
Size
4.54 MB
Format
Adobe PDF
Checksum (MD5)
39c29232704f4e2b63f9106ba082641e
Author(s) • • • • •
Wei, Quantum J.
Tucker, Carson I.
Wu, Priscilla J.
Trueworthy, Ali M.
Tow, Emily W.
Lienhard, John H
Alternative Title
Impact of salt retention on true batch reverse osmosis energy consumption: Experiments and model validation
Date Issued
February 2020
Journal
Desalination
Publisher
Elsevier BV
Citation
Lei, Quantum J. et al. "Impact of salt retention on true batch reverse osmosis energy consumption: Experiments and model validation." Desalination, 479 (April 2020): 114177
Version
Author's final manuscript
Abstract
In theory, the batch reverse osmosis (RO) process achieves the lowest practical energy consumption by varying pressure over time. However, few batch RO systems have been built and operated. We have designed, built, and operated the first “true” batch RO prototype using a flexible bladder. The flexible bladder serves as the high-pressure variable-volume tank that is inherent to true batch RO designs (as opposed to batch RO with energy recovery devices). We experimentally validated a model of batch RO energy consumption (≤2.7% difference) by measuring the hydraulic work of the high pressure and circulation pumps. We find that batch RO energy consumption will be greater than expected mostly due to salt retention, a problem neglected by most previous studies. However, despite operating at elevated salinity and flux conditions, batch RO can still save energy relative to single-stage and multi-stage continuous systems. For a seawater desalination plant (35 g/kg intake, 50% recovery, 15 L m [superscript−2] h [superscript−1]), our newly-validated model predicts that batch RO would save 11% energy compared to a single-stage continuous RO plant. Our work demonstrates that batch RO is an energy-efficient process with the potential to reduce the cost of water desalination. Keywords: Desalination; Reverse osmosis; Batch reverse osmosis; Salt retention; Energy efficiency
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Rohsenow Kendall Heat Transfer Laboratory (Massachusetts Institute of Technology)
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version