Non-invasive cardiovascular magnetic resonance assessment of pressure recovery distance after aortic valve stenosis

Thumbnail Image
Download
Name

12968_2023_Article_914.pdf

Size

2.39 MB

Format

Adobe PDF

Checksum (MD5)

84178802feeaff132a79c2431c2416cd

Download all files submitted through automated deposit
art_4272234791505184870.zip (1.94 MB)
Author(s)
Fernandes, Joao F.
•
Gill, Harminder
•
Nio, Amanda
•
Faraci, Alessandro
•
Galli, Valeria
•
Marlevi, David
•
Bissell, Malenka
•
Ha, Hojin
•
Rajani, Ronak
•
Mortier, Peter
more
Date Issued
January 30, 2023
Publisher
BioMed Central
Citation
Journal of Cardiovascular Magnetic Resonance. 2023 Jan 30;25(1):5
Version
Final published version
Abstract
Abstract Background Decisions in the management of aortic stenosis are based on the peak pressure drop, captured by Doppler echocardiography, whereas gold standard catheterization measurements assess the net pressure drop but are limited by associated risks. The relationship between these two measurements, peak and net pressure drop, is dictated by the pressure recovery along the ascending aorta which is mainly caused by turbulence energy dissipation. Currently, pressure recovery is considered to occur within the first 40–50 mm distally from the aortic valve, albeit there is inconsistency across interventionist centers on where/how to position the catheter to capture the net pressure drop. Methods We developed a non-invasive method to assess the pressure recovery distance based on blood flow momentum via 4D Flow cardiovascular magnetic resonance (CMR). Multi-center acquisitions included physical flow phantoms with different stenotic valve configurations to validate this method, first against reference measurements and then against turbulent energy dissipation (respectively n = 8 and n = 28 acquisitions) and to investigate the relationship between peak and net pressure drops. Finally, we explored the potential errors of cardiac catheterisation pressure recordings as a result of neglecting the pressure recovery distance in a clinical bicuspid aortic valve (BAV) cohort of n = 32 patients. Results In-vitro assessment of pressure recovery distance based on flow momentum achieved an average error of 1.8 ± 8.4 mm when compared to reference pressure sensors in the first phantom workbench. The momentum pressure recovery distance and the turbulent energy dissipation distance showed no statistical difference (mean difference of 2.8 ± 5.4 mm, R2 = 0.93) in the second phantom workbench. A linear correlation was observed between peak and net pressure drops, however, with strong dependences on the valvular morphology. Finally, in the BAV cohort the pressure recovery distance was 78.8 ± 34.3 mm from vena contracta, which is significantly longer than currently accepted in clinical practise (40–50 mm), and 37.5% of patients displayed a pressure recovery distance beyond the end of the ascending aorta. Conclusion The non-invasive assessment of the distance to pressure recovery is possible by tracking momentum via 4D Flow CMR. Recovery is not always complete at the ascending aorta, and catheterised recordings will overestimate the net pressure drop in those situations. There is a need to re-evaluate the methods that characterise the haemodynamic burden caused by aortic stenosis as currently clinically accepted pressure recovery distance is an underestimation.
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/147883
DOI of Published Version
https://doi.org/10.1186/s12968-023-00914-3
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.