Instrument guide for MRI-guided percutaneous interventions

Thumbnail Image
Download
Name

676694191-MIT.pdf

Description
Full printable version
Size

9.43 MB

Format

Adobe PDF

Checksum (MD5)

bf8498fe403b15a196d3a3dac3b179f7

Author(s)
Chen, Xuefeng, S.B. Massachusetts Institute of Technology
Advisor(s)
Alexander H. Slocum.
Alternative Title
Instrument guide for Magnetic Resonance Imaging-guided percutaneous interventions
Date Issued
2010
Publisher
Massachusetts Institute of Technology
Abstract
As MRI guided interventions are becoming more widely practiced, the goal of this thesis was to design an instrument guidance device for MRI-guided percutaneous interventions in closed bore systems, namely cryoablation procedures where multiple probes need to be placed to treat a tumor. Multiple meetings with researchers and clinicians the Brigham and Women's Hospital were conducted to understand the challenges currently faced by interventionists, to set functional requirements for the design of a system to overcome them, and to help select a clinically viable strategy. The strategy selected involved making a device that had two degrees of angular freedom about a remote center of motion located at the probe entry point on the skin. This device is designed to be incorporated with a custom built MR coil. Structural and finite element analysis was conducted for a number of different mechanism concepts to examine their stiffness and the effect of structural displacements on the end-point probe placement accuracy. The selected concept was a curved arm piece that travels around the pivot point on a circular base, and an additional needle holder that travels along the curved arm. The sliding parts were designed with five points of constraint so that only sliding motion was possible. Thumb screws were used for preload and locking so that the probe guide could be locked along a specific trajectory. The device was prototyped via stereolithography as a proof of concept. It was found that sanding was required to fit the parts together because of overbuild in the stereolithography process. The parts functioned as designed and demonstrated that a probe could be angled about a remote pivot point. However, wear of the plastic parts eventually caused increased play between the plastic parts. Further testing and optimization of the device is planned.
Description
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 50).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/59900
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.