Design of a single element 3D ultrasound scanner

Thumbnail Image
Download
Name

931029423-MIT.pdf

Description
Full printable version
Size

47.12 MB

Format

Adobe PDF

Checksum (MD5)

730e03bb9f665798a6bb0597bf727575

Author(s)
Zhang, Xiang, Ph. D. Massachusetts Institute of Technology
Advisor(s)
Brian W. Anthony.
Alternative Title
Design of a single element three-D ultrasound scanner
Design of a single element three-dimensional ultrasound scanner
Date Issued
2015
Publisher
Massachusetts Institute of Technology
Abstract
Over the past decade, substantial effort has been directed toward developing ultrasonic systems for medical imaging. With advances in computational power, previously theorized scanning methods such as ultrasound tomography can now be realized. This thesis presents the design, error analysis, and initial image reconstructions from a single element 3D ultrasound tomography system. The system enables volumetric pulse echo or transmission imaging of distal limbs, for applications including: improving prosthetic fittings, monitoring bone density, and characterizing muscle health. The system is designed as a flexible mechanical platform for iterative development of algorithms targeting imaging of soft tissue with bone. The mechanical system independently controls movement of two single element ultrasound transducers in a cylindrical water tank. Each transducer can independently circle about the center of the tank as well as move vertically in depth. High resolution positioning feedback (~1[mu]m) and control enables flexible positioning of the transmitter and the receiver around the cylindrical tank; exchangeable transducers enable algorithm testing with varying transducer frequencies and beam geometries. High speed data acquisition (DAQ) through a dedicated National Instrument PXI setup streams digitized data directly to the host PC. System positioning error has been quantified and is within limits for the desired imaging modality. Imaging of various objects including: calibration objects, phantoms, bone, animal tissue, and human forearm are presented accordingly.
Description
Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
Cataloged from student-submitted PDF version of thesis.
Includes bibliographical references (pages 90-92).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/100306
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.