Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Thumbnail Image
Download
Name

093531_1_5.0219340.pdf

Description
Published version
Size

4.98 MB

Format

Adobe PDF

Checksum (MD5)

f9b96b203f626d1ecb67e8a18d0d7d84

sword-2026-03-12T15:51:50.original.xml (130 B)
Original SWORD entry document
Author(s)
Buschmann, BI
•
Cufari, M
•
Vanderloo, N
•
Vargas, J
•
Foo, BC
•
DeVault, A
•
Dannhoff, SG
•
Evans, TE
•
Johnson, TM
•
Kunimune, JH
more
Date Issued
September 20, 2024
Journal
Review of Scientific Instruments
Publisher
AIP Publishing
Citation
B. I. Buschmann, M. Cufari, N. Vanderloo, J. Vargas, B. C. Foo, A. DeVault, S. G. Dannhoff, T. E. Evans, T. M. Johnson, J. H. Kunimune, Y. Lawrence, J. A. Pearcy, B. L. Reichelt, C. W. Wink, L. Russell, M. Gatu Johnson, R. D. Petrasso, J. A. Frenje; Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates. Rev. Sci. Instrum. 1 September 2024; 95 (9): 093531.
Version
Final published version
Abstract
Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.
MIT Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/165099
DOI of Published Version
https://doi.org/10.1063/5.0219340
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.