The M.I.T. Blowdown Compressor Facility
Name
09673833.pdf
Size
4.93 MB
Format
Adobe PDF
Checksum (MD5)
3918a06708e3f9d399b0657a4d8df3bc
Author(s)
Kerrebrock, Jack L.
Alternative Title
MIT Blowdown Compressor Facility
Massachusetts Institute of Technology Blowdown Compressor Facility
Date Issued
1972
Publisher
Cambridge, Mass. : Gas Turbine Laboratory, Massachusetts Institute of Technology, [1972]
Series/Report no.
GTL report #108
Abstract
A Blowdown Compressor Test Facility has been developed which allows aerodynamic testing of full-scale compressor stages at low cost. The rotor is brought to speed in vacuum, a diaphragm is opened, and the test gas allowed to flow for a time of the order of one tenth second, during which the rotor is driven by its own inertia. Both "steady state" performance evaluation and detailed time resolution of the flow on the blade-passing time scale have been demonstrated in a preliminary way for a two-foot diameter transonic rotor with tangential Mach number of 1.2 and nominal pressure ratio of 1.6.
Description
May, 1972
Includes bibliographical references (leaf 70)
Persistent DSpace Link