Performance limits of zero and single extraction humidification-dehumidification desalination systems
Name
2013 McGovern Performance Limits of Single and Dual Stage Humidification Dehumidification Desalination Systems.pdf
Size
1.21 MB
Format
Adobe PDF
Checksum (MD5)
2475bcaab0a4245e1f3e4b53759a5961
Author(s) • • • •
Zubair, Syed M.
McGovern, Ronan Killian
Thiel, Gregory Parker
Narayan, G. Prakash
Lienhard, John H
Date Issued
July 2012
Journal
Applied Energy
Publisher
Elsevier
Citation
McGovern, Ronan K., Gregory P. Thiel, G. Prakash Narayan, Syed M. Zubair, and John H. Lienhard. “Performance Limits of Zero and Single Extraction Humidification-Dehumidification Desalination Systems.” Applied Energy 102 (February 2013): 1081–1090.
Version
Author's final manuscript
Abstract
Given simultaneous heat and mass transfer and a multiplicity of possible temperature and flow configurations, the optimization of humidification-dehumidification desalination systems is complex. In literature, this optimization has been tackled by considering moist air to follow the saturation curve in the humidifier and dehumidifier of a closed air water heated cycle. Under similar conditions and the same pinch point temperature differences, energy recovery was shown to improve with an increasing number of stages. In the present work, the limits upon the energy recovery and the water recovery (product water per unit of feed) of closed air water heated cycles are investigated. This is done by considering heat and mass exchangers to be sufficiently large to provide zero pinch point temperature and concentration differences with in the humidifier and dehumidifier. For cycles operating with a feed temperature of 25 °C and a top air temperature of 70 °C, GOR is limited to approximately 3.5 without extractions (i.e. single stage system) and 14 with a single extraction (i.e. dual stage system) while RR is limited to approximately 7% without extractions and 11% with a single extraction. GOR increases and RR decreases as the temperature range of the cycle decreases, i.e. as the feed temperature increases or the top air temperature decreases. A single extraction is shown to be useful only when heat and mass exchangers are large in size. In addition, the effects of salinity and the validity of ideal gas assumptions upon the modeling of HDH systems are discussed.
MIT Department
Massachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Lab
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1016/j.apenergy.2012.06.025