Assessing the accuracy of low-cost optical particle sensors using a physics-based approach
Name
amt-13-6343-2020.pdf
Description
Published version
Size
1.52 MB
Format
Adobe PDF
Checksum (MD5)
10a664575499683eae91e911370fba90
Author(s) •
Hagan, David H
Kroll, Jesse H
Date Issued
November 2020
Journal
Atmospheric Measurement Techniques
Publisher
Copernicus GmbH
Citation
Hagan, D. H. and Kroll, J. H.: Assessing the accuracy of low-cost optical particle sensors using a physics-based approach, Atmos. Meas. Tech., 13, 6343–6355, 2020
Version
Final published version
Abstract
Low-cost sensors for measuring particulate matter (PM) offer the ability to understand human exposure to air pollution at spatiotemporal scales that have previously been impractical. However, such low-cost PM sensors tend to be poorly characterized, and their measurements of mass concentration can be subject to considerable error. Recent studies have investigated how individual factors can contribute to this error, but these studies are largely based on empirical comparisons and generally do not examine the role of multiple factors simultaneously. Here, we present a new physics-based framework and open-source software package (opcsim) for evaluating the ability of low-cost optical particle sensors (optical particle counters and nephelometers) to accurately characterize the size distribution and/or mass loading of aerosol particles. This framework, which uses Mie theory to calculate the response of a given sensor to a given particle population, is used to estimate the fractional error in mass loading for different sensor types given variations in relative humidity, aerosol optical properties, and the underlying particle size distribution. Results indicate that such error, which can be substantial, is dependent on the sensor technology (nephelometer vs. optical particle counter), the specific parameters of the individual sensor, and differences between the aerosol used to calibrate the sensor and the aerosol being measured. We conclude with a summary of likely sources of error for different sensor types, environmental conditions, and particle classes and offer general recommendations for the choice of calibrant under different measurement scenarios.
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Massachusetts Institute of Technology. Department of Chemical Engineering
Terms of Use
Creative Commons Attribution 4.0 International license
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.5194/AMT-13-6343-2020