Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Expected sensitivity to 128Te neutrinoless double beta decay with the CUORE TeO2 cryogenic bolometers

Expected sensitivity to 128Te neutrinoless double beta decay with the CUORE TeO2 cryogenic bolometers

Thumbnail Image
Download
Name

10909_2022_Article_2738.pdf

Size

884.78 KB

Format

Adobe PDF

Checksum (MD5)

a621eba8465564c4b080428f698e5430

Download all files submitted through automated deposit
art_5666498341180233301.zip (651.3 KB)
Author(s)
Dompè, V.
•
Adams, D. Q.
•
Alduino, C.
•
Alfonso, K.
•
Avignone, F. T.
•
Azzolini, O.
•
Bari, G.
•
Bellini, F.
•
Benato, G.
•
Beretta, M.
more
Date Issued
June 13, 2022
Publisher
Springer US
Citation
Dompè, V., Adams, D. Q., Alduino, C., Alfonso, K., Avignone, F. T. et al. 2022. "Expected sensitivity to 128Te neutrinoless double beta decay with the CUORE TeO2 cryogenic bolometers."
Version
Final published version
Abstract
Abstract The CUORE experiment is a ton-scale array of $$\hbox {TeO}_2$$ TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of $$\sim 10$$ ∼ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of $$^{130}\hbox {Te}$$ 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of $$^{128}\hbox {Te}$$ 128 Te . This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of $$^{130}\hbox {Te}$$ 130 Te . As the first ton-scale infrastructure operating cryogenic $$\hbox {TeO}_2$$ TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor $$>10$$ > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/143484
DOI of Published Version
https://doi.org/10.1007/s10909-022-02738-4
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.