REEV SENSE IMUs for Spatiotemporal Gait Analysis in Post-Stroke Patients: Validation Against Optical Motion Capture
Name
sensors-26-00667.pdf
Size
477.21 KB
Format
Adobe PDF
Checksum (MD5)
42a842266e319deaf305e4ad205b46d8
Author(s) • • • • • • • •
Marsan, Thibault
Clauzade, Sacha
Zhang, Xiang
Grandin, Nicolas
Urman, Tatiana
Linton, Evan
Sibachir, Samy
Ricciardi, Catherine E.
Temporelli, Robin
Date Issued
January 18, 2026
Journal
Sensors
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Marsan, T.; Clauzade, S.; Zhang, X.; Grandin, N.; Urman, T.; Linton, E.; Sibachir, S.; Ricciardi, C.E.; Temporelli, R. REEV SENSE IMUs for Spatiotemporal Gait Analysis in Post-Stroke Patients: Validation Against Optical Motion Capture. Sensors 2026, 26, 667.
Version
Final published version
Abstract
Objective gait assessment is essential for post-stroke rehabilitation monitoring, yet optical motion capture systems remain inaccessible to most clinical settings due to cost and infrastructure constraints. This study assessed the validity of the REEV SENSE IMU for measuring spatiotemporal gait parameters in post-stroke individuals and evaluated assistive device effects on measurement accuracy. Twenty chronic post-stroke participants were enrolled, and fourteen completed the study (ten without an assistive device, four using a cane) after applying pre-defined exclusion criteria (walking speed <0.28 m/s, n = 6). Participants walked at self-selected speed while simultaneously being recorded by REEV SENSE IMUs and optical motion capture. Spatiotemporal parameters from matched heel strikes were compared using intraclass correlation coefficients (ICC), mean relative error (MRE), and Bland–Altman analysis. Temporal parameters demonstrated excellent reliability: contact time (ICC 0.96–0.99, MRE 2.77–5.45%), stride duration (ICC 0.95–0.99, MRE 2.57–2.62%), and cadence (ICC 0.98–0.99, MRE 1.80–1.93%). Spatial parameters showed greater variability, with stride length degrading substantially in slow-walking conditions (Cane group: ICC 0.76, MRE 8.60%). REEV SENSE provides reliable temporal parameter measurement comparable to commercial systems, positioning it as a practical tool for clinical gait monitoring in post-stroke rehabilitation. However, spatial parameter accuracy requires cautious interpretation in slow-walking regimes, necessitating independent validation when clinical decisions depend on precise stride length estimates.
MIT Department
Massachusetts Institute of Technology. Center for Clinical and Translational Research
Institute for Medical Engineering and Science
Terms of Use
Creative Commons Attribution
Persistent DSpace Link
DOI of Published Version
http://dx.doi.org/10.3390/s26020667