  4. Optimization of ultraviolet Raman spectroscopy for trace explosive checkpoint screening

Optimization of ultraviolet Raman spectroscopy for trace explosive checkpoint screening

Thumbnail Image
Download
Name

216_2020_2725_ReferencePDF.pdf

Size

1.57 MB

Format

Adobe PDF

Checksum (MD5)

82574e29312fba1a3f10fa8644a96272

Download all files submitted through automated deposit
art_486165989365614897.zip (1.46 MB)
Author(s)
Amin, Mitesh
•
Wen, Patrick
•
Herzog, William D
•
Kunz, Roderick R
Date Issued
May 29, 2020
Publisher
Springer Berlin Heidelberg
Version
Author's final manuscript
Abstract
Abstract Raman spectroscopy has long been considered a gold standard for optically based chemical identification, but has not been adopted in non-laboratory operational settings due to limited sensitivity and slow acquisition times. Ultraviolet (UV) Raman spectroscopy has the potential to address these challenges through the reduction of fluorescence from background materials and increased Raman scattering due to the shorter wavelength (relative to visible or near-infrared excitation) and resonant enhancement effects. However, the benefits of UV Raman must be evaluated against specific operational situations: the actual realized fluorescence reduction and Raman enhancement depend on the specific target materials, target morphology, and operational constraints. In this paper, the wavelength trade-space in UV Raman spectroscopy is evaluated for one specific application: checkpoint screening for trace explosive residues. The optimal UV wavelength is evaluated at 244, 266, and 355 nm for realistic trace explosive and explosive-related compound (ERC) residues on common checkpoint materials: we perform semi-empirical analysis that includes the UV penetration depth of common explosive and ERCs, realistic explosive and ERC residue particle sizes, and the fluorescence signal of common checkpoint materials. We find that while generally lower UV wavelength provides superior performance, the benefits may be significantly reduced depending on the specific explosive and substrate. Further, logistical requirements (size, weight, power, and cost) likely limit the adoption of optimal wavelengths. Graphical abstract
MIT Department
Lincoln Laboratory
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/131840
DOI of Published Version
https://doi.org/10.1007/s00216-020-02725-2
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.