Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Systematic evaluation of chromosome conformation capture assays

Systematic evaluation of chromosome conformation capture assays

Thumbnail Image
Download
Name

s41592-021-01248-7.pdf

Description
Published version
Size

18.3 MB

Format

Adobe PDF

Checksum (MD5)

58fa7fe06837c0ec77954c3381700a41

sword-2021-12-09T13:55:20.original.xml (130 B)
Original SWORD entry document
Author(s)
Akgol Oksuz, Betul
•
Yang, Liyan
•
Abraham, Sameer
•
Venev, Sergey V
•
Krietenstein, Nils
•
Parsi, Krishna Mohan
•
Ozadam, Hakan
•
Oomen, Marlies E
•
Nand, Ankita
•
Mao, Hui
more
Date Issued
September 2021
Journal
Nature Methods
Publisher
Springer Science and Business Media LLC
Citation
Akgol Oksuz, Betul, Yang, Liyan, Abraham, Sameer, Venev, Sergey V, Krietenstein, Nils et al. 2021. "Systematic evaluation of chromosome conformation capture assays." Nature Methods, 18 (9).
Version
Final published version
Abstract
Chromosome conformation capture (3C) assays are used to map chromatin interactions genome-wide. Chromatin interaction maps provide insights into the spatial organization of chromosomes and the mechanisms by which they fold. Hi-C and Micro-C are widely used 3C protocols that differ in key experimental parameters including cross-linking chemistry and chromatin fragmentation strategy. To understand how the choice of experimental protocol determines the ability to detect and quantify aspects of chromosome folding we have performed a systematic evaluation of 3C experimental parameters. We identified optimal protocol variants for either loop or compartment detection, optimizing fragment size and cross-linking chemistry. We used this knowledge to develop a greatly improved Hi-C protocol (Hi-C 3.0) that can detect both loops and compartments relatively effectively. In addition to providing benchmarked protocols, this work produced ultra-deep chromatin interaction maps using Micro-C, conventional Hi-C and Hi-C 3.0 for key cell lines used by the 4D Nucleome project.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Terms of Use
Creative Commons Attribution 4.0 International license
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/138405
DOI of Published Version
https://doi.org/10.1038/s41592-021-01248-7
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.