Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Flexible liquid crystal polymer-based electrochemical sensor for in-situ detection of zinc(II) in seawater

Flexible liquid crystal polymer-based electrochemical sensor for in-situ detection of zinc(II) in seawater

Thumbnail Image
Download
Name

Microchimica Acta_Nan WANG.pdf

Description
Accepted version
Size

896.14 KB

Format

Adobe PDF

Checksum (MD5)

80484120efa0c9514d765ed7b1051438

sword-2020-08-10T16:25:20.original.xml (130 B)
Original SWORD entry document
Author(s)
Wang, Nan
•
Kanhere, Elgar
•
Kottapalli, Ajay Giri Prakash
•
Miao, Jianmin
•
Triantafyllou, Michael S
Date Issued
May 2017
Journal
Microchimica Acta
Publisher
Springer Science and Business Media LLC
Citation
Wang, Nan. "Flexible liquid crystal polymer-based electrochemical sensor for in-situ detection of zinc(II) in seawater." Microchimica Acta 184, 8 (May 2017): 3007–3015 © 2017 Springer-Verlag
Version
Author's final manuscript
Abstract
The authors describe a liquid crystal polymer (LCP) based bismuth (Bi) film electrode that can be directly deployed for in-situ determination of zinc(II) ions. The use of an LCP warrants improved operational reliability, high durability, and flexibility of the sensor, allowing it to be mounted on any flat or shaped surface. Square wave anodic stripping voltammetry shows the sensor to be able to detect Zn(II) (−1.64 V vs. thin-film Ag/AgCl reference electrode) in concentrations as low as 1.22 nM at a deposition time of 180 s. Other figures of merit include (a) an analytical sensitivity of 1.55 nA∙nM−1∙mm−2, (b) a linear detection range extending from 4.59 to 1071 nM, (c) a repeatability with a relative standard deviation of 3.35% (for n = 10), (d) a reproducibility with a relative standard deviation of 1.64% (for n = 6). Real-time applicability of the sensor for in-situ detection was demonstrated by determination of Zn(II) in seawater. In an extension of the method, a flexible sensor array consisting of four LCP-based sensors was attached to the hull of an autonomous kayak, which was remotely operated. The response of the sensor array indicated a clear trace of Zn(II) concentrations in seawater. This was confirmed by ICP-MS analysis. The results suggest the potential usage of the flexible LCP electrochemical sensor for in-situ monitoring.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/128657
DOI of Published Version
https://doi.org/10.1007/s00604-017-2280-6
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.