Sensitivity of Seismically Cued Antineutrino Detectors to Nuclear Explosions

Thumbnail Image
Download
Name

PhysRevApplied.10.024014.pdf

Size

458.86 KB

Format

Adobe PDF

Checksum (MD5)

e2db39c5f62b77c52257b36a6ba265b7

Download all files submitted through automated deposit
PhysRevApplied.10.024014-mets.zip (317.64 KB)
Author(s)
Carr, Rachel
•
Dalnoki-Veress, Ferenc
•
Bernstein, Adam
Date Issued
August 2018
Journal
Physical Review Applied
Publisher
American Physical Society
Citation
Carr, Rachel et al. "Sensitivity of Seismically Cued Antineutrino Detectors to Nuclear Explosions." Physical Review Applied 10, 2 (August 2018): 024014 © 2018 American Physical Society
Version
Final published version
Abstract
We evaluate the sensitivity of large gadolinium-doped water detectors to antineutrinos released by nuclear-fission explosions, using updated signal and background models and taking advantage of the capacity for seismic observations to provide an analysis trigger. Under certain realistic conditions, the antineutrino signature of a 250-kton pure-fission explosion could be identified several hundred kilometers away, in a detector about the size of the largest module currently proposed for a basic physics experiment. In principle, such an observation could provide rapid confirmation that the seismic signal coincided with a fission event, possibly useful for international monitoring of nuclear-weapon tests. We discuss the limited potential for seismically cued antineutrino observations to constrain fission yield, differentiate pure fission from fusion-enhanced weapon tests, indicate that the seismic evidence of an explosion had been intentionally masked, or verify the absence of explosive testing in a targeted area. We conclude that advances in seismic monitoring and neutrino physics have made the detection of explosion-derived antineutrinos more conceivable than previously asserted, but the size and cost of sufficiently sensitive detectors continue to limit applications.
MIT Department
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/117345
DOI of Published Version
https://doi.org/10.1103/PhysRevApplied.10.024014
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.