Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Libraries
  3. MIT Theses
  4. Graduate Theses
  5. Wide-field magnetic field imaging with nitrogen vacancy centers in nanodiamonds at high frame-rates

Wide-field magnetic field imaging with nitrogen vacancy centers in nanodiamonds at high frame-rates

Thumbnail Image
Download
Name

953583409-MIT.pdf

Description
Full printable version
Size

16.11 MB

Format

Adobe PDF

Checksum (MD5)

451af9b7d540a4ebace49f83c24291a6

Author(s)
Foy, Christopher, Ph. D. (Christopher C.) Massachusetts Institute of Technology
Advisor(s)
Dirk Englund.
Date Issued
2016
Publisher
Massachusetts Institute of Technology
Abstract
The nitrogen vacancy center (NV) is a promising single spin system in diamond with optical polarization, readout and optically detected magnetic resonances (ODMR). The NV has been shown to be a sensitive magnetometer at room temperature. In particular, owing to their small size, NV centers in nanocrystals (nanodiamonds) offer magnetic field imaging with high spatial resolution. Competitive magnetic field imaging methods such as magnetic force microscopy (MFM) or superconducting quantum interference devices (SQUID) either image serially, and are thus slow, or are limited in their use for biological systems. Nanodiamonds in contrast have the advantage that they can be attached to biological tissues in vivo and can be imaged in parallel at high speeds. Unfortunately, nanodiamonds tend to aggregate due to Coulomb interactions of their surface species. This aggregation results in a inhomogeneous broadening of the NV's ODMR with applied magnetic field. This broadening makes imaging magnetic fields non-trivial. In this work, we present a model to understand aggregated nanodiamonds. Despite NVs with defined crystallographic orientations demonstrating vectorial resolution of magnetic fields, this model predicts that aggregated nanodiamonds should be treated as absolute magnetometers. Further, a sparse sampling protocol is implemented that enables time resolved magnetometry and is used to image the magnetic field of a current carrying wire at greater than 33 Hz speeds with magnetic field sensitivities better than ... over a 10 [mu]m x 10 [mu]m field of view.
Description
Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2016.
Cataloged from PDF version of thesis.
Includes bibliographical references (pages 83-88).
Subjects
Electrical Engineering and Computer Science.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/103750
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.