A Numerical Solution Algorithm for a Heat and Mass Transfer Model of a Desalination System Based on Packed-Bed Humidification and Bubble Column Dehumidification
Name
IHTC15-8995_revised.pdf
Description
Main article
Size
768.75 KB
Format
Adobe PDF
Checksum (MD5)
09f9d4f8182414d1bf23f6060f8dd39d
Author(s) • •
Cheaib, Farah K.
Chehayeb, Karim Malek
Lienhard, John H
Date Issued
August 2014
Journal
Proceedings of the 15th International Heat Transfer Conference
Publisher
Begell House Inc.
Citation
Chehayeb, Karim, Farah K. Cheaib, and John H. Lienhard. “A Numerical Solution Algorithm for a Heat and Mass Transfer Model of a Desalination System Based on Packed-Bed Humidification and Bubble Column Dehumidification.” Proceedings of the 15th International Heat Transfer Conference (2014).
Version
Author's final manuscript
Abstract
The humidification-dehumidification (HDH) desalination system can be advantageous in small-scale, off-grid applications. The main drawback of this technology has been its low energy efficiency, which results in high water production costs. Previous studies have approached this issue through thermodynamic balancing of the system; however, most theoretical work on the balancing of HDH has followed a fixed-effectiveness approach that does not explicitly consider transport processes in the components. Fixing the effectiveness of the heat and mass exchangers allows them to be modeled without explicitly sizing the components and gives insight on how the cycle design can be improved. However, linking the findings of fixed-effectiveness models to actual systems can be challenging, as the performance of the components depends mainly on the available surface areas and the flow rates of the air and water streams. In this study, we present a robust numerical solution algorithm for a heat and mass tranfer model of a complete humidification-dehumidification system consisting of a packed-bed humidifier and a multi-tray bubble column dehumidifier. We look at the effect of varying the water-to-air mass flow rate ratio on the energy efficiency of the system, and we compare the results to those reached following a fixed-effectiveness approach. In addition, we study the effect of the top and bottom temperatures on the performance of the system. We recommended the implementation a control system that varies the mass flow rate ratio in order to keep the system balanced in off-design conditions, especially with varying top temperature.
MIT Department
Massachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Lab
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1615/IHTC15.eef.008995