Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Vessel centerline reconstruction from non-isocentric and non-orthogonal paired monoplane angiographic images

Vessel centerline reconstruction from non-isocentric and non-orthogonal paired monoplane angiographic images

Thumbnail Image
Download
Name

10554_2017_1275_ReferencePDF.pdf

Size

1.32 MB

Format

Adobe PDF

Checksum (MD5)

852fe115ead9ace03f8c339e2aacfcdf

Download all files submitted through automated deposit
art_1439180204952146630.zip (1.19 MB)
Author(s)
Bailey, Lynn
•
Lemos, Pedro A.
•
Tearney, Guillermo J.
•
Kunio, Mie
•
O'Brien, Caroline C.
•
Lopes Jr, Augusto Celso de Araujo
•
Edelman, Elazer R
Date Issued
November 2017
Journal
The International Journal of Cardiovascular Imaging
Publisher
Springer Netherlands
Citation
Kunio, Mie, Caroline C. O’Brien, Augusto C. Lopes, Lynn Bailey, Pedro A. Lemos, Guillermo J. Tearney, and Elazer R. Edelman. “Vessel Centerline Reconstruction from Non-Isocentric and Non-Orthogonal Paired Monoplane Angiographic Images.” The International Journal of Cardiovascular Imaging (November 14, 2017).
Version
Author's final manuscript
Abstract
Purpose Three-dimensional reconstruction of a vessel centerline from paired planar coronary angiographic images is critical to reconstruct the complex three-dimensional structure of the coronary artery lumen and the relative positioning of implanted devices. In this study, a new vessel centerline reconstruction method that can utilize non-isocentric and non-orthogonal pairs of angiographic images was developed and tested. Methods Our new method was developed in in vitro phantom models of bifurcated coronary artery with and without stent, and then tested in in vivo swine models (twelve coronary arteries). This method was also validated using data from six patients. Results Our new method demonstrated high accuracy (root mean square error = 0.27 mm or 0.76 pixel), and high reproducibility across a broad imaging angle (20°–130°) and between different cardiac cycles in vitro and in vivo. Use of this method demonstrated that the vessel centerline in the stented segment did not deform significantly over a cardiac cycle in vivo. In addition, the total movement of the isocenter in each image could be accurately estimated in vitro and in vivo. The performance of this new method for patient data was similar to that for in vitro phantom models and in vivo animal models. Conclusions We developed a vessel centerline reconstruction method for non-isocentric and non-orthogonal angiographic images. It demonstrated high accuracy and good reproducibility in vitro, in vivo, and in clinical setting, suggesting that our new method is clinically applicable despite the small sample size of clinical data. Keywords Coronary angiography Image reconstruction Reconstruction algorithm Stereoscopic theory
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/116229
DOI of Published Version
https://doi.org/10.1007/s10554-017-1275-z
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.