Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Low-volume multiplexed proteolytic activity assay and inhibitor analysis through a pico-injector array

Low-volume multiplexed proteolytic activity assay and inhibitor analysis through a pico-injector array

Thumbnail Image
Download
Name

612b58b65678b4ef1e61dbe4367d5411064e.pdf

Size

1.23 MB

Format

Adobe PDF

Checksum (MD5)

e91384dec9c5aa2d4696cb0879ade8d0

Download all files submitted through automated deposit
sword-2018-09-10.original.zip (1.04 MB)
Author(s)
Ng, Ee Xien
•
Jing, Tengyang
•
Chen, Chia-Hung
•
Miller, Miles Aaron
•
Lauffenburger, Douglas A
Date Issued
December 2014
Journal
Lab on a Chip
Publisher
Royal Society of Chemistry (RSC)
Citation
Ng, Ee Xien, et al. “Low-Volume Multiplexed Proteolytic Activity Assay and Inhibitor Analysis through a Pico-Injector Array.” Lab on a Chip, vol. 15, no. 4, 2015, pp. 1153–59. © 2015 The Royal Society of Chemistry
Version
Author's final manuscript
Abstract
Secreted active proteases, from families of enzymes such as matrix metalloproteinases (MMPs) and ADAMs (a disintegrin and metalloproteinases), participate in diverse pathological processes. To simultaneously measure multiple specific protease activities, a series of parallel enzyme reactions combined with a series of inhibitor analyses for proteolytic activity matrix analysis (PrAMA) are essential but limited due to the sample quantity requirements and the complexity of performing multiple reactions. To address these issues, we developed a pico-injector array to generate 72 different reactions in picoliter-volume droplets by controlling the sequence of combinational injections, which allowed simultaneous recording of a wide range of multiple enzyme reactions and measurement of inhibitor effects using small sample volumes (~10 μL). Multiple MMP activities were simultaneously determined by 9 different substrates and 2 inhibitors using injections from a pico-injector array. Due to the advantages of inhibitor analysis, the MMP/ADAM activities of MDA-MB-231, a breast cancer cell line, were characterized with high MMP-2, MMP-3 and ADAM-10 activity. This platform could be customized for a wide range of applications that also require multiple reactions with inhibitor analysis to enhance the sensitivity by encapsulating different chemical sensors. This journal is
MIT Department
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Biology
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/117703
DOI of Published Version
https://doi.org/10.1039/C4LC01162G
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.